SGP30 - USER MANUAL 
Space Guard Proximity Series

 

 

Photoelectric light curtain 

 

Website:  www.telcosensors.com

 

 

 Warning

 

V 1.1 Part Number: 0666220765

 

E-Mail:     info@telcosensors.com 

 

This product is not a safety system and must not be used as such. 
It is not designed for personnel safety applications, and must not be used 
as a stand alone personnel safety system. 

April 2015 edition 

 

Made in Denmark

 

Telco A/S reserves the right to make changes without prior notice 

 

 

tel

EN 

Product Data 

 

Electrical Data 

Supply voltage 

12 — 30 V dc 

Max. voltage ripple 

15 % (within supply range) 

Max. current consumption 

120 mA (RMS) 

Max. output load 

200 mA 

Output Reverse polarity protected 

Yes 

Output short circuit protected 

Yes 

Output inductive load protection 

Yes 

 

Environmental Data 

Light immunity @5º incidence 

> 100.000 lux 

Temperature, operation 

-30 to + 60 ºC 

Sealing class 

 IP 67 

Marking 

 

 

Available Models 

Model 

Beam spacing 

Sensing Range 

SGP 30-xxx-0xx-A1-M-xx-xx 

46 mm 

1,3 m 

 

Connection

 

 

Wiring Diagrams

 

 

    
 
                             

 

 

SGP30 5 pin M12 male connector 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

Wiring diagram 

 

Installation & Adjustments

 

 

Adjustment

 

Mount the SGP30 unit.  

Wire the sensor according to the wiring diagram.  
Make sure the output load does not exceed 200 mA. 

Check for correct wiring before turning power on. 

When the power on indicator (green LED) is on the system is operating. 

Use the control wire to blank any IR channels which unintended has proximity effect on 
the output or decrease the sensing range. 

Adjust the sensing range with potentiometer mounted in the top plastic plug of the rail. 

If necessary use the control wire again to blank any IR channels which unintended has 
proximity effect on the output. 

After power on make sure that the output indicator (yellow LED) change state when an 
object is placed in front of the rails and within the sensing range. 

The light curtain is only intended for static applications. 

 

Output Logic 

Detection 

Output mode 

Output status 

Output indicator 

(yellow LED) 

Object present 
 
 
 

Dark operated 

(N.C.) 

Open 

Off 

Light operated 

(N.O.) 

Closed 

On 

Object absent 
 
 

Dark operated 

(N.C.) 

Closed 

On 

Light operated 

(N.O.) 

Open 

Off 

 
 

Adjusting sensing range                                                                                                                

With the potentiometer mounted in the top plastic plug of the rail the sensing range can be 
adjusted from 0 m to 1,3 m. The sensing range is at its maximum when the potentiometer is 
fully clock wise. Notice that when increasing the sensing range it can be necessary to blank IR 
beams because nearby objects unintentionally can be detected. 

 

Blanking function mode, Ctrl input

This function is used to blank out beams that otherwise constantly would detect close lying 
surfaces or objects, for instance construction elements as metallic frames, support pillars or 
beams. When an IR beam is blanked it cannot change the state of the output. 
 
The blanking mode is activated by powering up the SGP30 with pin 2 (white Ctrl wire) 
connected to ground (-). In this mode every IR beam that detects something, even temporarily, 
will be blanked and stored in non-volatile memory. Pin 2 should at least be connected to 
ground as long as the output indicates that one or more IR beams detects objects and the red 
LED is not lit. If there are movement in close laying objects this can take some seconds. 
 
When the blanking procedure is finish pin 2 must be removed from ground (-) before power to 
the SGP30 is removed, otherwise no IR beams will be blanked. During normal operation pin 2 
must be left floating. The blanking is now permanent, also after power down, until new 
blanking has been made. 
The green LED will flash three times after power-up if any IR beams are blanked. 
 
If blanking shall be deactivated there are two options: 

1.

 

Repeat blanking process, but without nearby objects or surfaces that can cause 
blanking. 

2.

 

Repeat blanking process, with the potentiometer turned to 0. 

 

Indicators

Red LED 

Status indicator 

Yellow LED 

Output indicator 

Green LED 

Power on indicator 

 

Troubleshooting

 

 

Probable Reason 

Corrective Action 

1.

 Symptom: Status indicator (Red LED) is constant on. 

SGP30 is in blanking mode and blanking 
is completed. 

Remove pin 2 from ground (-). 

Internal failure. 

Return SGP30 unit to factory.  

 

2.

 Symptom: Output indicator (Yellow LED) on is flashing. 

Severe electrical interference. 

Separate supply cable from high voltage cables. 

Severe ambient light. 

Shield, reposition or twist SGP30. 

Cross talk from another light curtain or 
photo sensor 

Shield or reposition SGP30 or other photo 
sensor. 

Cross talk from a nearby HF strip light 

Shield, reposition or twist SGP30. 

 

3.

 Symptom: With NO output red LED, yellow LED is constant on and output is closed. 

One or more IR beams have proximity 
effect. 

If necessary perform a blanking process or 
remove object(s) or lower amplification by 
turning potentiometer anti clock wise. 

 

4.

 Symptom: With NC output red LED and yellow LED is constant off and output is open. 

One or more IR beams have proximity 
effect. 

If necessary perform a blanking process or 
remove object(s) or lower amplification by 
turning potentiometer anti clock wise. 

 

5.

 Symptom: Red LED is off and output is stocked. 

SGP30 is out of sensing range. 

Adjust the sensing range with potentiometer. 

 

Disposal

 

 

Disposal should be done using the most up-to-date recycling technology according to local 
rules and laws. 

 

 

 
 
 
 
 
 

1 2 

1: Brown 
2: White 
3: Blue 
4: Black 
5: Black or Yellow/green

 