elmeg DECT200 Multicell System / en / elmegDECT200M_en / using.fm / 18.10.2013
V
e
rsion 1, 01.0
7
.2012
21
elmeg DECT200 Multicell System
bintec elmeg
Operating information
LEDs on the base stations
The elmeg DECT200 base stations contain two DECT modules with separate status displays.
Other displays:
u
The second LED from the top (
Power/LAN
) flickers when you are restoring the factory
settings to indicate that the resetting process will begin as soon as you release the reset
button (
From top to bottom
Status of DECT module 1
Power supply status If the power supply is OK, the LED
indicates the LAN connection status.
Status of DECT module 2
Reset button (
Power/LAN 1/2
DECT 1/2
Description
Off
Off
No power supply / No supply voltage
Flashes (once a
second)
Off
The base station is looking for the DECT
Manager
On
Off
Connection established to DECT Manager, base
station service not yet ready
Flashes (every two
seconds)
Off
Firmware is being updated, base station service
not active
On
On
Base station DECT module ready, DECT
synchronised
On
Flashes (every four
seconds)
Base station DECT module ready, DECT not
synchronised
Flashes (every four
seconds)
On
Base station DECT module overloaded, DECT
synchronised
Flashes (every four
seconds)
Flashes (every four
seconds)
Base station DECT module overloaded, DECT
not synchronised
Please note
You can deactivate the base station LED displays using the Web configurator on the DECT
Manager (
DECT 1
Power/LAN
Power/LAN
DECT 2
RESET
Summary of Contents for BinTec Elmeg DECT200
Page 3: ......