ethernet0/0 PSE+registers
Example:
ethernet0/0 PSE+registers
Registers for device 0 (ports 5-8)
0 ... 00 f1 00 -- 00 -- 00 --
8 ... 00 -- 00 -- 00 00 00 00
10 ... 00 34 00 00 00 00 00 a0
Interrupt: not pending
Registers for device 1 (no ports)
0 ... 00 f1 00 -- 00 -- 00 --
8 ... 00 -- 00 -- 00 00 00 00
10 ... 00 30 00 00 00 00 00 a0
Interrupt: not pending
ethernet0/0 PSE+
2.3.7 RESTART-PSE
Restarts the PSE control. All ports are powered off and all devices are restarted.
Syntax:
ethernet0/0 PSE+restart-pse
Example:
ethernet0/0 PSE+list-status
POE cards: - POE card 1 (Ports 5-8)
Available PSE output power = 120000 mW
Minimum PSE output power
= 7000 mW
POE output power per port
= As requested
Ports Status
Port 5: Detect Signature Resistance Low
Port 6: Detect Good, Class2, requested 7000 mW, applied 7000 mW
Port 7: Detect Open Circuit
Port 8: Detect Open Circuit
ethernet0/0 PSE+restart-pse
ethernet0/0 PSE+list-status
POE cards: - POE card 1 (Ports 5-8)
Available PSE output power = 120000 mW
Minimum PSE output power
= 0 mW
POE output power per port
= As requested
Ports Status
Port 5: Disabled
Port 6: Disabled
Port 7: Disabled
Port 8: Disabled
ethernet0/0 PSE+list-status
POE cards: - POE card 1 (Ports 5-8)
Available PSE output power = 120000 mW
Minimum PSE output power
= 7000 mW
POE output power per port
= As requested
Ports Status
Port 5: Detect Signature Resistance Low
Port 6: Detect Good, Class2, requested 7000 mW, applied 7000 mW
Port 7: Detect Open Circuit
Port 8: Detect Open Circuit
ethernet0/0 PSE+
2.3.8 EXIT
Use the EXIT command to exit the power sourcing equipment monitoring menu and to return to the main Ethernet
ethernet0/0 ETH+
interface monitoring menu.
Teldat SA
2 Monitoring
PoE Power over Ethernet
13