Model 458-CC-16/458-CM (16-Slot Chassis & Control Module) Rev I
Page 40
9. When returned to the
Change Setup
menu, type option
1
to configure Channel 1.
Note
:
There are several Channel 1 options that can be configured. The ones to make note of are the
following:
a.
Baudrate:
This will be important to know for settings up serial communication in remote
terminal software.
b.
Port No:
This is the TPC port number to be used over a telnet connection. The default
is
10001
.
c.
DisConnMode:
The default value for this is
00
. Entering the value
40
for this parameter
will allow controlling the unit remotely via telnet. This is indicated as
<Telnet Com Port
Cntrl Enabled>
Note
: When the
DisConnMode
is set to
40
, there may be odd characters displayed if using remote
terminal software such as HyperTerminal. It is recommended to only enable this feature if controlling
it via telnet.
10. At the
Change Setup
menu, enter
9
to Save and exit.
The message “
Parameters stored. Connection to Host lost
” is shown. The Telnet window closes
automatically and the update is now complete.
11. If telnet com port control has been enabled, it can be tested right from the command prompt.
12. Enter
telnet <IP address> <TCP port>
. Example: telnet 172.16.21.241 10001.
13. Enter
h
for help to display the list of commands for the 458-3SLB. This will verify
communication.