Model 458-CC-16/458-CM (16-Slot Chassis & Control Module) Rev I
Page 42
ed
Echo disable
Inputs not echoed and format output for user control program
h
Help RS232 command list
Read RS232 command list
cs:BR
Configure serial
Where BR = 300, 600, 1200, 2400, 4800, 9600 or 19200
cp:ADD
Configure 488
Where ADD = 1, 2, ... 29, 30 (No leading zeroes used)
Set Length command
sl:LM:H:LE,C
Where:
LM = Module slot number
→
01
– 16
H = Channel number
→
1 - 8
LE = Length (in feet)
C = Connect mode:
N = connect both CO and CPE ends.
P = connect CPE only CO is open.
O = connect CO only CPE is open.
Z = open both CO and CPE ends
Example: SL:01:1:2000,N sets channel 1 to 2000 ft for a line module in slot 1.
The connect mode may be used to create an “open loop” condition at either the CO or CPE
ends, or both.