Model 458-LM-E1-36-04 Multi-Standard Local Loop Simulator
Page 4
Control
The Model 458-LM-E1-36-04 can be controlled three ways: via RS-232 and IEEE488 Remote
Commands, our 458 Universal GUI interface or the push buttons and LCD Display on the front
panel of our 458-3SLx or 458-CM.
Remote Commands
Please refer to the manuals for the 458-3SLB or 458-CC-16/458-CM for remote commands
common to many line modules, including the 458-LM-E1-36-04. This manual contains
commands unique to this module.
RS-232 (Serial Port) Remote Commands
Set Length Command Values: SL:M:LE,C
Where,
SL = set length
M = module (slot) number 01
– 16 (458-CM) or 01-03 (458-3SLB)
LE = length from 0
– 9,000 m in steps of 10 m
C = connect mode
N = connect both CO and CPE ends
P = connect CPE only CO open
O = connect CO only CPE open
Z = open both CO and CPE ends
Example:
SL:02:9000,N = Set length of module in slot 02 to 9000 meters with both CO and CPE
connected.