Model 458-LM-E1-36-04 Multi-Standard Local Loop Simulator
Page 5
Read Length Command Values: RL:M
Where,
RL = read length
M = module (slot) number 01
– 16 (458-CM) or 01-03 (458-3SLB)
Example:
RL:02 = Read length of module in slot 02.
3.2 Graphical User Interface
Refer to the 458 Universal Graphical User Interface Reference Manual for more information.
3.3 LCD Display/Front Panel
Basic Operation
Make selections by pushing the UP, DOWN, LEFT and RIGHT arrow buttons on the front panel.
The LCD Display shows the choices made. Refer to the chassis manual for additional details.
Step One
– Select Slot
•
Navigate to the desired slot in the 458-3SLx (3-Slot) Chassis or 458-CC16/458-CM
(16-Slot) Chassis using the UP or DOWN arrows.
Step Two
– Select Increment
•
Step through the allowable lengths for the current slot using the LEFT or RIGHT arrow
buttons. The length will increment in 10-m steps.
Step Three
– Select Noise Levels
•
Use the UP arrow button to select the CO or CPE noise.
•
Adjust the noise level using the LEFT and RIGHT arrow buttons.