Telecast Fiber Systems
Repair
Call Telecast Fiber Systems, Inc. for assistance with the Adder 161 System at
508-754-4858 and ask for our service department. To return a unit for repair, you
must obtain a return material authorization (RMA) number from Telecast service.
Digital Characteristics
Signal Levels
RS-422 interface uses balanced TTL levels
RS-232 interface uses TTL levels
Data Rate
RS-422
Balanced TTL levels
0-150 KBits/sec*
RS-423
TTL levels
0-150 KBits/sec*
RS-232
±8 Vp-p
0-19.2 KBits/sec
Jitter
1.12 msec
*higher rates possible dependent on user system jitter tolerance
Contact Closure
TX Input
TTL 1 or open circuit (remote contact open)
TTL 0 or shorted to circuit ground (remote contact closed)
RX Output (Form 1A SPST-NO isolated contacts)
Voltage
200 VDC
Switched current
500 mA
Carry current
1.2 Amps
Contact resistance
200 M
Optical Characteristics
Wavelength 850, 1300 and 1550nm
Power Requirements
Voltage 12 to 24 VDC
Current 1.5 Amps, nominal
Note: Although the units will operate at 12 VDC, 13.8 VDC is required to charge the
internal reserve battery.
WARNING: Absolute maximum voltage is 30 VDC.
Equipment damage may occur at higher voltages.