Optical Characteristics
System Margin Data (1-fiber/2-fiber)
Operating Wavelength
1300 nm
1550 nm
TX Output into cable
-15/-13 dBm
-15/-13 dBm
RX Sensitivity
-28/-30 dBm
-28/-30 dBm
Power Requirements
Voltage
12 to 24 VDC
Current
1.5 amperes, maximum @ 13.8 VDC
NOTE:
Although the units will operate at 12 VDC, 13.8 VDC is required to charge
the internal reserve battery.
CAUTION: Absolute maximum voltage is 30 VDC. Equipment damage may
occur at higher voltages.