background image

Adder AES-8

Warranty

LIMITED WARRANTY STATEMENT

Telecast Fiber Systems, Inc. (“Telecast”) expressly warrants to Buyer that the Products supplied shall be free
from defects in materials and workmanship for a period of 12 months following the date the Products are deliv-
ered to Buyer (the “Warranty Period”). Telecast's liability under this limited warranty shall be limited, at its option,
to providing refund of purchase price for Products, or replacing or repairing Products shown to be defective
either in materials or workmanship. Buyer's sole and exclusive remedy for breach of warranty shall be such
refund, replacement or repair.
A claim of defect in materials or workmanship in any Product shall be allowed only when it is submitted in writing
to Telecast Fiber Systems, Inc. within seven days after discovery of the defect, and in any event within the
Warranty Period. No claim shall be allowed in respect of any Product which has been altered, neglected, dam-
aged or stored in any manner which adversely affects it. In order to obtain service under the terms of this
warranty, Distributor’s customer or Distributor must notify Telecast of the defect prior to the expiration of the
applicable warranty period and obtain a Return Authorization Number from Telecast. In no event may products be
returned to Telecast or to Distributor for warranty service without having obtained from Telecast a Return Autho-
rization Number.
This limited warranty applies only to new and unused Products delivered to Buyers located within the United
States of America, or to international Buyers if sold through an authorized Distributor organization, and shall not
extend to any equipment not manufactured by Telecast Fiber Systems, Inc., even though such equipment may be
sold or operated with the Products. In addition, this limited warranty shall be void and of no further force or effect
whatsoever if the Product is repaired or modified by any person other than an authorized representative of
Telecast Fiber Systems, Inc. without the consent of Telecast Fiber Systems, Inc. This warranty shall not apply to
any defect, failure or damage caused by improper use or inadequate maintenance and care. Nor shall this
warranty apply to any damage caused in whole or in part by attempts by personnel other than Telecast’s person-
nel, as approved in advance in accordance with the foregoing provisions, to open, install, repair, or service the
Product; nor to damage resulting from improper connection with incompatible equipment; nor to damage to a
unit which has been modified by personnel other than Telecast personnel.
Products returned to Telecast for warranty service shall be shipped, freight prepaid to Telecast. Telecast will
return the repaired product or ship a replacement, freight prepaid, to either Distributor or Distributor’s customer,
as requested by Distributor’s customer, at a location within the United States or, at Telecast’s option, to
Distributor’s location in the case of international sales.
This limited warranty shall also apply to Products that replace defective Products and Products that have been
repaired by authorized representatives of Telecast Fiber Systems, Inc., but only for the original Warranty Period.
The Warranty Period shall not be extended by reason of defect, or any period of time during which the Product is
not available to Buyer because of defects or repairs, without the express written consent of Telecast Fiber
Systems, Inc.
EXCEPT FOR THE EXPRESS LIMITED WARRANTY AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP
CONTAINED HEREIN, TELECAST FIBER SYSTEMS, INC. MAKES NO WARRANTY OF ANY KIND WHATSOEVER,
EXPRESS OR IMPLIED, AND ALL WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PUR-
POSE, AND OTHER WARRANTIES OF WHATEVER KIND ARE HEREBY DISCLAIMED BY TELECAST FIBER
SYSTEMS, INC. THIS LIMITED WARRANTY SETS FORTH EXCLUSIVELY ALL OF TELECAST FIBER SYSTEMS,
INC.'S LIABILITY IN CONTRACT OR OTHERWISE IN THE EVENT OF A DEFECTIVE PRODUCT.
WITHOUT LIMITATION ON THE FOREGOING, TELECAST FIBER SYSTEMS, INC. EXPRESSLY DISCLAIMS ANY
LIABILITY WHATSOEVER FOR ANY DAMAGES INCURRED DIRECTLY OR INDIRECTLY IN CONNECTION WITH
THE SALE OR USE OF, OR OTHERWISE IN CONNECTION WITH, THE PRODUCT, INCLUDING WITHOUT LIMITA-
TION, LOSS OF PROFITS AND SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES, WHETHER CAUSED BY
NEGLIGENCE OR OTHERWISE, REGARDLESS WHETHER TELECAST HAS BEEN GIVEN ADVANCE NOTICE OF
THE POSSIBILITY THEREOF.
THIS WARRANTY IS GIVEN BY TELECAST IN LIEU OF ANY OTHER WARRANTY EXPRESSED OR IMPLIED.

8

Summary of Contents for Adder AES-8

Page 1: ...Adder AES 8 Digital Audio Multiplexer Instruction Manual Telecast Fiber Systems Inc 102 Grove Street Worcester MA 01605 Tel 508 754 4858 Fax 508 752 1520 www telecast fiber com...

Page 2: ...Adder AES 8 ii...

Page 3: ...and Rear 4 RX front and rear 5 Fiber and Electical hook Ups 6 Introduction 1 System Components 1 System Features 1 Advantages 1 Applications 2 Theory of operation 2 Power 2 TX Feature Descriptions 4 R...

Page 4: ...Adder AES 8 Adder AES 8 Transmitter Top and Receiver bottom iv...

Page 5: ...any damage to the carrier and to Telecast Fiber Systems Inc System Features Eight stereo AES Digital Audio channels or 16 audio channels User selectable sampling rates of 32 44 056 44 1 and 48 KHz Ext...

Page 6: ...two channels of digitized information along with clocks flags and user information Once a signal is received it derives the sample rate clock frequency for synchronization of the 8 input channels An...

Page 7: ...Telecast Fiber Systems Figure 1 Mounting Dimensions 3 19 00 17 25 14 62 1 75...

Page 8: ...in the AES position D SYNC The red LED when lit indicates the unit is not receiving an external sync signal Functional only when EXT is selected for the SAMPLE RATE E SUPPLY INDICATORS Four green LED...

Page 9: ...t channels E LINK Green LED indicates fiber integrity is good F SYNC The red LED when lit indicates the unit is not receiving the external sync signal This indicator is used when EXT is selected for t...

Page 10: ...to EXT for external sync The AES 8 will then detect and synchronize to the first valid AES input signal of the eight AES Digital inputs For the Rx unit the SAMPLE RATE switch can be set to the known s...

Page 11: ...an optical attenuator of at least 15dBm may be needed to reduce the potential of overloading the receiver Troubleshooting and Repair 7 In the unique case where you have a AES Digital signal with a unk...

Page 12: ...quate maintenance and care Nor shall this warranty apply to any damage caused in whole or in part by attempts by personnel other than Telecast s person nel as approved in advance in accordance with th...