10
1 2 3
ON
1 2 3
ON
3.1 Deactivation of wireless safety system
This function is possible ONLY within 30 seconds from the power on of the control unit.
• Step 1: switch the unit off
By default DIP1 is ON (system activated).
• Step 2: switch the unit on and move DIP1 to OFF within 30 seconds
ON
to
OFF
The control unit will emit
6
beeps if the system has been correctly deactivated.
Note: it is possible activate the safety system again, moving the DIP1 from OFF to ON within 30 seconds
from power-on. After keeping pressed for 5 seconds button P1, the control unit will emit
7
beeps to signal
that the system has been activated.
• Step 3: press the programming button P1 for 5 seconds and hold it down
WARNING: according to the safety standards of door automation, after the deactivation of
the safety system it is necessary setting the HOLD-TO-RUN mode with DIP2 to OFF (p. 9).
3.2 Exclusion of safety edge in the last 5 cm of the closure
In case of uneven floors, it could be necessary deactivating the safety edge in the last part of the closure (not
more than 5 cm to comply with the standards) in order to avoid any accidental activation of the safety edge.
This procedure must be performed by qualified installer only, who will take charge of its correct application.
WARNING: this procedure can be used only for doors which require more than 10 seconds each
manoeuvre. It can be started only within 30 seconds after the power-ON. The exclusion of the safety
edge is applied only if the closure starts from the upper limit switch and it is not stopped.
Press
P1
button
ten times
and keep it pressed
for
5 seconds
. The buzzer emits 3 beeps.
( 5 s)
STOP
max. 5 cm
• Open the door
completely
(in
hold-to-run
mode) by means of a memorized transmitter. The
buzzer emits a long beep when the upper limit
switch is reached. Put on the floor, exactely under
the door, a sturdy object not more than 5 cm high.
• Close the door (in
hold-to-run
mode), with
no
interruption
. The door will stop at the obstacle
and the control unit will make a long beep.
Open the door
completely
and remove the
object. Close the door to verify the correct
application of the procedure.
hold-to-run
X
( 5 s)
keep it pressed
DEACTIVATION
WITHIN 30
SEC. FROM
POWER-ON
STOP
Press
P1
button
eleven times
and keep it
pressed for
5 seconds
. The buzzer emits 5
beeps.
WITHIN 30
SEC. FROM
POWER-ON
keep it pressed
hold-to-run