21
www.behnke-online.com
Instructions Secure Ethernet Adapter / Secure Door Adapter
Secure Ethernet Adapter
GB
Installation inside the Behnke on-wall housing:
Mounting material provided:
▸
1 x elbow for the sabotage contact incl.
2 x stud bolts inside/outside M 2.5 x 18 mm
▸
2 x Phillips screws M2.5 x 6 mm V2A
▸
Sabotage contact
For mounting in a Series 50 AP housing:
▸
2 x stud bolts M 2.5 x 5 mm inner/outer
▸
2 x Phillips screws M 2.5 x 4 mm
1. First, remove the bottom of the module
housing free of drillings and spacings from
the electronics box.
2. Now, put the bottom of the module housing
with drillings and spacings in place and fix it
to the door intercom's base housing.
3. Use the Phillips screws M2.5 x 6 mm to
fix the sabotage contact together with the
18 mm spacing.
*
4. Now, please perform a function test on the
sabotage contact with a multimeter. When
you insert the sabotage contact into the
on-wall housing, the sabotage contact will
be activated and closed. Do not connect
the sabotage contact to the Secure Ethernet
Adapter. With the sensing device activated,
you should be able to measure a resist-
ance of 5.1 kΩ on the screw terminals. After
testing, please connect the sabotage contact
to the Secure Ethernet Adapter inside the
building.
*
Fix the stud bolts M 2.5 x 5 inner / outer on top of the spacers.
Use the Phillips screws M 2.5 x 4 mm to fix the sabotage contact.
Please note: Connection clamps facing.
Up
Bottom of module housing with necessary
preparations to hold the sabotage contact
Sabotage contact mounted
For mounting in a Series 50 AP housing, please turn
the sabotage contact 180° (with the connection
contacts facing the basic electronics)
180°