14
Changing power supply voltage
1.
Disconnect the power of receiver.
2.
Remove the connector plug of the transformer from its original
position.
3.
Insert the connector plug into the new position.
4.
Complete the procedure.
Transformer
Jumper
24/48
VAC
48/110
VAC
48/220
VAC
110/220
VAC
220/380
VAC
LO position
24VAC
48VAC
48VAC 110VAC 220VAC
HI position
48VAC 110VAC 220VAC 220VAC 380VAC
Note:
Users are allowed to select the different power source according to the
respective requirement. However, the transformer must be changed.
Please check with your local distributor for replacement of the
transformer if necessary.
2-5 Function Setting
This remote control system can be set according to the working
condition and operator’s need for the following purposes: specific
pushbutton function, EMS neglected function, Auto-off time,
interference neglected time…etc. This enables the remote controller to
perform the most effective operation and to provide the safest operation.
Please refer to the Software Function Setting in Chapter 3, next chapter.
Note:
Through the USB cable, F21-E2 PC software can easily read/write
the e-Card of transmitter or receiver. If you just need to copy the e-
Card, the transmitter will also provide easy, quick copy function as well.