17
Function Setting
Definition
Inching 1 &2
The relative relay will be conducted within a certain time, in order to operate
with short and precision movement. There are 2 ways to perform this function:
Inching 1
: Once “START” pushbutton is pressed, just presses the relative motion
pushbutton then can perform inching motion. To release this function,
just press “START” pushbutton again.
Inching 2
: Pres
s and hold “START” pushbutton and press the relative motion
pushbutton to perform inching motion.
Inching Time
“Inching time” can be set from 0. 1~
3.0 seconds. This function is used to operate
crane wi
th short and precise movement (e.g. accurate position). “Inching Time”
is the same as the working time for the relative relay that is controlled by
executing “Inching” control function.
Transmission Mode
Non-continuous transmitting mode
:
After “Power
-
On”,
the transmitter will
transmit the signal only when the pushbutton is pressed. This mode can save the
power of transmitter.
Continuous transmitting mode
: Transmitter will continuously transmit signal
once transmitter is being Power-On.
Auto Off (TX)
This function refers to turn off the Transmitter after a given idle time while
transmitting the STOP signal to switch off the receiver.
*Only available under “continuous transmitting” mode.
e-Card Copy
Enable/Disable: Select
“
Enable
”
to unlock the e-Card Read/write protected for
being duplicated by copier. Or
“
Disable
”
to lock the e-Card Read/write protected
for being duplicated by copier.
LED OFF-Time
This setting allows you to select the LED intermittent time to save transmitter
power. i.e.:
If 1 second is being selected, the LED will be lighted 0.6 second and
off 1 second as cycle.
TX Power
The emission power of the transmitter is adjustable according to the user’
s
requirement. This option is providing 5 stages for controlling distance. The
higher emission power, it consumes more battery power.
Start-Alarm
This function allows the user to activate R0 relay for controlling external alarm
device during Power-On and Power-Off the receiver. The duration is available
from 2~6 seconds.
Passive EMS
This setting allows user to select the radio interfering duration can be bypassed.
If the radio interfering duration not exceeds the “
Passive EMS
” setting time, then
the receiver is still in operation. If the interfering duration exceeds the setting
time, then the receiver will stop working. This stop action is called "
Passive
EMS
".