122188-10 A0
Telect, Inc.
4-1
4
Software Operation
M
ANAGING
A S
YSTEM
You can configure, test, and monitor a system using these interfaces:
•
Via Ethernet Port located on rear of chassis (one per system):
◊
SNMP (Simple Network Management Protocol) Interface
◊
Craft Interface over Telnet connection (up to two Telnet sessions)
◊
TL1 Interface over Telnet connection (up to two Telnet sessions)
•
Via Craft Port (serial port) on front of chassis (one per system):
◊
Craft Interface over RS232 serial connection
◊
TL1 Interface over RS232 serial connection
•
Via Remote Control:
If the MIX 56 is connected over the DS3 link to another MIX 56 and
they are both in C-bit mode on the DS3 link, then a remote control ses-
sion can be run where the user is controlling the MIX 56 at the remote
end of the DS3 link.
◊
Craft Interface over DS3 Link
◊
TL1 Interface over DS3 Link
ALERT
!
ALERT! It is possible to have multiple active sessions at the
same time involved in configuring the same system. It is possi-
ble to have five active sessions at the same time: one via the
serial port; two via Telnet connections; one SNMP; and one via
Remote Control.
Summary of Contents for MIX 56
Page 1: ... MIX 56 122188 10 A0 USER MANUAL ...
Page 6: ...vi Telect Inc 122188 10 A0 ...
Page 10: ...x Telect Inc 122188 10 A0 ...
Page 100: ...4 Software Operation MIX 56 User Manual 4 54 Telect Inc 122188 10 A0 ...
Page 116: ...5 Owner Maintenance MIX 56 User Manual 5 16 Telect Inc 122188 10 A0 ...
Page 123: ......