3.3 Reversing the Door Swing
Procedure steps:
1. Open the door.
2. Unplug any wires connected
to the door.
3. On Bay 1 or the single bay’s front
door, unplug the wire harness from
the heat exchanger.
4. Disconnect the windstay bracket at
the bottom, inside corner of the en-
closure by using a 7/16” socket to
remove the two 1/4-20 Keps nuts
(circled in Figure 8) and flatwashers
from the bracket. Set the hardware
aside for reuse.
5. Disconnect the door’s ground wire
from the frame. Follow the ground wire to the frame
connection point. Use a 7/16” socket to remove the
1/4-20 keps nut. Set the hardware aside for reuse.
6. Locate the hinges and hinge pins on the left side.
Figure 8 - Windstay Bracket
Figure 9 -
Disconnecting the Ground Wire
Ground wire
Hinge & Pin