07773B DCN6940
11
2
SPECIFICATIONS AND APPROVALS
2.1 Specifications
Table 2
-
1: Specifications
Parameter
Specification
Output
10 SLPM at 30 psig
Max delivery pressure
30 psig
Dewpoint*
< -20
°
C
Dryer
Regenerative heatless dryer with lifetime of greater than 5 years
Output Concentration
SO
2
<0.025 ppb
NO <0.025 ppb
NO
2
<0.025 ppb
O
3
<0.3 ppb
CO < 10 ppb
HC < 0.25 ppb
Compressor
Single-cylinder, internal long-life, oil-less piston pump
Dimensions
9” x 22” x 13.8” (229 x 559 x 351 mm)
Weight
47 lbs (21.3 kg)
Operating Temp
5-40
°
C
Power
Typical Power Consumption
110-120 V~ 60 Hz, 4.0 A
220-240 V~ 50 Hz, 3.0 A
320 W
425 W
Environmental Conditions
Installation Category (Over Voltage Category ) II Pollution Degree 2
Intended for Indoor Use Only at Altitudes
≤
2000m
Mains Supply Voltage Fluctuations not to exceed
±
10% of the
nominal voltage.
Transient Over Voltages according to Over Voltage Category II
* 230V/50Hz regions can expect normal operation at 6 SLPM or less, at 40 Degree Celsius and saturated ambient conditions.
The pump’s ability to maintain pressure, and thus meet dew point specification, also degrades with altitude above 6000 feet.