083730510A DCN8172
Teledyne API T500U CAPS NO
2
Analyzer with NumaView™ Software
39
MENU OVERVIEW
Table 2-6 describes the main menus and provides cross-references to the respective
sections with configuration details.
Table 2-6. Menu Overview
MENU
DESCRIPTION
LOCATION
Home
View and plot concentration readings and other selectable parameter
values (Figure 2-21).
Section 2.4.1
Dashboard
View user-selected parameters and their values, some of which can be
displayed in a live-plot graph (Figure 2-22).
Section 2.4.2
Alerts
View and clear active Alerts that were triggered by factory-defined Events
as well as user-defined Events. (Active and past Alerts are recorded in
the Utilities>Alerts Log).
Section 2.4.3
Calibration
Run calibrations on the NO and NOx channels and calibrate converter
efficiency points.
Sections 2.4.4
and 4
Utilities
View logs, download data and firmware updates, copy configurations
between instruments, and run diagnostics.
Section 2.4.5
Setup
Configure a variety of features and functions through these submenus for
customized operation.
Section 2.5
Datalogging
Track and record concentration and calibration data and
selectable diagnostic parameters, the reports for which can
be viewed in the Utilities>Datalog View menu (Section 2.4.5)
and downloaded to a flash drive via the Utilities>USB Utilities
menu (Section 2.4.5).
Also, select configured Events (Section 2.5.2) and create
customized triggers for data logging functions.
Section 2.5.1
Events
Select parameters and define the conditions by which they
are to be flagged and recorded in the Alerts log (Section
2.4.3) when they are triggered. Once configured, Events can
be used to trigger Datalogs. (Section 2.5.1). Note that some
Events are predefined and are not editable.
Section 2.5.2
Dashboard Monitor instrument functionality (Figure 2-19) via selectable
parameters.
Section 2.5.3
Auto Cal
(with valve options)
When zero/span valve options installed, configure
sequences for automatic calibration functions.
Section 4.3
Vars
Manually adjust several software variables that define
specific operational parameters.
Section 2.5.5
Homescreen Select up to three parameters to be displayed in the meters
Section 2.5.6
Digital
Outputs
Map the rear-panel digital outputs to a variety of signals
present in the instrument to monitor the status of operating
conditions or custom Events.
Section 2.5.7
Analog
Outputs
Send user-selected parameter readings in the form of user-
defined voltage or current loop signals as outputs to a strip
chart recorder and/or the data logger.
Section 2.5.8
Instrument
View product and system information, including list of
options, if any; view network settings; view/adjust Date and
Time settings
*
; and check for firmware updates when
connected to a network that is connected to the Internet.
*
Time Zone change requires special procedures (Section 5.5).
Section 2.5.9
Comm
View and configure network and serial communications.
Section 2.5.10