Optical Modulation Analyzer
10
Power
LabMaster power ratings vary by model. If you are using LabMaster components other than those
shipped as part of an OMA system, see the product datasheet at teledynelecroy.com for power ratings.
Component
AC Power Source*
Max. Consumption
(all accessories installed) Standby Consumption
MCM-Zi-A
100 to 240 VAC (±10%) at
50/60 Hz (± 10%)
≤ 450 watts (450 VA)
5 W
LM 10-36Zi-A
LM 10-25Zi-A
100 to 240 VAC (±10%) at
50/60 Hz (± 10%)
≤ 1225 watts (1225 VA)
12 W
LM 10-65Zi-A
100 to 240 VAC (±10%) at
50/60 Hz (± 10%)
≤ 1275 watts (1275 VA)
12 W
IQS25, IQS40, IQS70
110 to 240 (±10%) VAC at
50/60 Hz (±10%)
≤ 20 watts (20 VA)
0 W
* The system automatically adapts to line voltage; manual voltage selection is not required.
Fuse Replacement
The coherent receiver is equipped with a user-replaceable AC mains fuse.
CAUTION
Unplug the power cord before inspecting or replacing the fuse to avoid electric shock.
1.
Open the black fuse holder (located at the rear of the instrument next to the mains inlet) using a small,
flat-bladed screw driver.
2.
Remove the old fuse and replace it with a new 5 X 20 mm T rated 1.0 A/250 V fuse.
3.
Replace the fuse holder.
Grounding
The MCM-Zi-A Master Control Module is provided with a 10A/250V rated grounded cord set containing a
molded three-terminal polarized plug with a standard IEC-60320 (Type C13) connector.
The LM 10-36Zi-A, LM 10-25Zi-A and LM 10-65Zi-A acquisition modules are provided with a 16A/250V or
15A/125V rated grounded cord set containing a molded three-terminal polarized plug and a specific IEC-
60320 (Type C19) connector.
The IQS25, IQS42 and IQS70 coherent receivers are provided with a 10A/250V rated grounded cord set
containing a molded three-terminal polarized plug and an IEC-60320 (Type C13) connector.
The power cords mate to a compatible AC power inlet on the back of the instruments for line voltage and
safety ground connections. The AC inlet ground is connected directly to the frame of the instrument. For
adequate protection again electric shock, connect to a mating outlet with a safety ground contact.
WARNING
To maintain ground, use only the power cord provided with each component. Interrupting
the protective conductor inside/outside the oscilloscope or disconnecting the safety
ground terminal creates a hazardous situation. Intentional interruption is prohibited.