Optical Modulation Analyzer
38
Equalizer Parameters (Equalizer)
The purpose of the equalizer is to correct frequency dependent distortion in the signal. It is an adaptive
Finite Impulse Response (FIR). Similar to the other stages you can add a Custom algorithm via MATLAB
or set it to None.
Control
Action
Gradient
This value controls the speed and accuracy of the adaptation. The value
ranges from 1e-6 to 1. Smaller numbers will result longer convergence time
over the training symbols but better results in presence of noise, and vice
versa for higher numbers. The default is a good compromise between the
two, as seen over a range of signals.
Symbols
Enter the length of the training set.
Num Taps
Enter the number of taps in the equalizer kernel.
Force to T/2 Taps
If selected, sets the taps per baud to 2. If left unselected, the taps per baud
is equal to the number of symbols.