background image

     Introduction 

The Teledyne LeCroy PCI Express 

Gen4 M.2 MKey Interposer CrossSync Phy

, which is used with Summit T54 Protocol 

Analyzers, enables PCIe

®

 bus traffic between a system board or tablet and a M.2 connector on a PCIe M.2 device to be 

monitored, captured, and recorded for protocol analysis. The M.2 interposer will support analysis for PCIe host interfaces 
such as SATA Express (AHCI/PCIe) and NVM Express (NVMe) at data rates from 2.5 GT/s up to 16.0 GT/s and link widths 
of up to x2 or up to x4.

The interposer supports side band signals such as PERST#, WAKE#, CLKREQ# and SMBus (SMBCLK, SMBDAT).The 
M.2 technology specification includes two connector definitions: Socket 2 and Socket 3. Socket 2 keyed as “B” allows for 
PCIe x2 interface for SSDs, WWAN or other non-storage devices. Socket 3 keyed as “M” is strictly for high-performance 
storage, offering x4 lanes of bandwidth in this form factor. In some cases a “B/M” keyed SSD will also be available and it is 
both a Socket 2 and 3 type. A “B”, “M” or a “B/M” keyed memory SSD can then be connected to a host based B or M 
connector which is capable of supporting any of the devices mentioned above.

Teledyne LeCroy provides an interposer to use with M and B-M type memory modules. The interposer supports the 30mm, 
42mm, 60mm, 80mm, and 110mm SSD lengths as well as 22mm and 30mm widths.

PCI Express Gen4 M.2 M-Key Interposer

PCI Express

®

 Gen4 M.2 M-Key Interposer 

CrossSync PHY 
User Manual and Quick Start Guide

Before Starting

Use this document for quick installation and setup. If you experience problems or 
need more information, see the product manuals available at the Teledyne LeCroy 
web site or in the Documents folder in the PCIe Protocol Suite installation.

1

Summary of Contents for PCI Express Gen4 M.2

Page 1: ...other non storage devices Socket 3 keyed as M is strictly for high performance storage offering x4 lanes of bandwidth in this form factor In some cases a B M keyed SSD will also be available and it is...

Page 2: ...tach and secure the Teledyne LeCroy M 2 interposer cable on the host system which usually supports different M 2 card form factors Follow below instructions to install the extension brackets that will...

Page 3: ...ble soldered to the top of the PCB was removed in the drawing below for clarity 5 Insert the Extension bracket with the clip into the PCB with cables attached Ensure that the alignment pins on the bra...

Page 4: ...nt bracket follow below procedure The Teledyne LeCroy M 2 Interposer Extension Bracket Kit contains the items listed below The items are shown in the figure below Type 22110 Extension bracket Type 228...

Page 5: ...er 5 The view from the top side of the PCB is shown below The text Type 2280 is clearly visible Attaching the Cables to the Interposer 1 Once the cable assembly has been completed Method One or Method...

Page 6: ...22110 Move the M 2 standoff based on the DUT Type The standoff will be attached to 2280 location by default The DUT is secured by a thumbscrew on the top side and a standoff with a locknut on the bot...

Page 7: ...it for it to be recognized by the application Note If prompted to update the firmware please do that before proceeding 9 Start recording with the analyzer 10 Power on the host machine 11 Launch the Te...

Page 8: ...to the next active width as indicated by the LEDs next to the switch on the interposer DUT Power LED Status on Interposer SW4 This switch connects the DUT power indication LEDs to the bus power In so...

Page 9: ...F Protocol Analyzer US Clock Cable A Side Band Test Point Header J6207 Connector Pin Number Signal Name Connector Pin Number Signal Name 1 No Connection 17 VIO_CFG_HDR 2 No Connection 18 No Connection...

Page 10: ...sis software and MAUI oscilloscope software optional Signal Name PE210UIA X PE210UIA X 1PHY PE210UIA X 2PHY PE210UIA X 4PHY Pin Headers CLK_32KHZ SUSCLK X X X X DAS DSS LED_1 X X X X ALERT IN X X X X...

Page 11: ...erential probe with ProLink interface DH08 PL 13 GHz differential probe with ProLink interface DH13 PL 16 GHz differential probe with ProLink interface DH16 PL 20 GHz differential probe with ProLink i...

Page 12: ...d Top View 2 Locate the PCIe Express pairs probe points as located on the left and right sides of the interposer Left Side View Right Side View Buffered Refclk Copy UMC Pin Header for Sideband Signals...

Page 13: ...nnect the oscilloscope probes to the PCI express signals as shown in the figure below Connect each Oscilloscope Probe to the Required PCIe Bus Signal Interposer Ready for a Scope Analysis of a PCIe x2...

Page 14: ...emarks of Teledyne LeCroy All other trademarks are property of their respective companies Changes Product specifications are subject to change without notice Teledyne LeCroy reserves the right to revi...

Reviews: