Input Specifications
The BOA vision system provides two dedicated opto-isolated, polarity independent
inputs. One of the inputs provides the acquisition Trigger function, while the other is
general purpose.
Specification
Definition
Voltage
ON
12-30 V
OFF
0-3 V (12 V nominal threshold)
Current
ON
7.5 mA typ (24 V applied)
Protection
Resistance
3K Ohms
Isolation
4000 V RMS
Common pin
Input
PWR or GND
Switch Time
ON
10 Microsecond
OFF
50 Microseconds
Latency
Trigger
62 Microseconds from trigger input to start of acquisition
The active polarity of each input is configured in the Sherlock Embedded Client
application. The camera includes a noise filter on the input which is also configurable.
To connect with an NPN source, connect the camera trigger input (pin 1) to the NPN
source output and the camera common input (pin 5) to PWR. When the source output
turns ON, the camera input will be pulled down turning the opto-coupler ON.
To connect with an PNP source, connect the camera trigger input (pin 1) to the PNP
source output and the camera common input (pin 5) to GND. When the source output
turns ON, the camera input will be pulled up turning the opto-coupler ON.
Input Diagram
NPN Wiring
PNP Wiring