Piranha HS-xx RoHS User Manual
Teledyne DALSA
03-032-20013-03
105
Item
(when programmable configuration the options are separated with a |
)
HS-80-08k40/80
Cam era Stand ard <N TSC, PAL, VS, VW, MW>
VS
Variable Wind ow
<Colu m n Start, Colu m n End , Row Start, Row End >
(0,0,0,0)
All zeros ind icates an u nsu p p orted
featu re
Mu ltip le Wind ow
N u m ber of Wind ow s (Colu m n Start 1, Colu m n End 1, Row Start 1, Row End
1) (Colu m n Start 2, Colu m n End 2,...)
0, (0,0,0,0)
All zeros ind icates an u nsu p p orted
featu re
Number of Camera Configurations<1,2,3,…>
8
Configu ration Definition
Cx= H DW, N u m ber of Ou tp u t Tap s, Bit Wid th, N u m ber of Processing N od es
w here
Cx is the configu ration ID x is <1,2,3…>
H DW is <Base, Med iu m , Fu ll>
Number of Output Taps is <1,2,3…>
Bit w id th is <8, 10, 12…>
N u m ber Processing N od es is <1 or 2>
TDI Mod e
C1 = Fu ll, 8, 8, 1
C2 = Fu ll, 8, 12, 1
C3 = Med iu m , 8, 8, 1
C4 = Med iu m , 8, 12, 1
Area Mod e
C5 = Fu ll, 8, 8, 1
C6 = Fu ll, 8, 12, 1
C7 = Med iu m , 8, 8, 1
C8 = Med iu m , 8, 12, 1
Tap Reconstru ction
In som e configu rations the reconstru ction m ay change. C0 is the d efau lt
output format and must be listed . Output configurations that d on’t conform
are listed sep arately.
<Cx,Tn (Colu m n Start, Colu m n End , Colu m n Increm ent, Row Start, Row
End , Row Increm ent>
H orizontal m irroring is su p p orted .
Mirror ―on‖ changes the follow ing
u nm irrored valu es to:
The sign of the colu m n increm ent
is inverted .
Colu m n Start becom es the
Colu m n End valu e
Colu m n End becom es the Colu m n
Start valu e
TDI Mod e Forw ard Direction left to
right read ou t
C1/ 2, T1 (1, 1024, 1, 1, 1, 1)
C1/ 2, T2 (1025, 2048, 1, 1, 1, 1)
C1/ 2, T3 (2049, 3072, 1, 1, 1, 1)
C1/ 2, T4 (3073, 4096, 1, 1, 1, 1)
C1/ 2, T5 (4097, 5120, 1, 1, 1, 1)
C1/ 2, T6 (5121, 6144, 1, 1, 1, 1)
C1/ 2, T7 (6145, 7168, 1, 1, 1, 1)
C1/ 2, T8 (7169, 8192, 1, 1, 1, 1)
C3/ 4, T1 (1, 2048, 1, 1, 1, 1)
C3/ 4, T2 (2049,4096 1, 1, 1, 1)
C3/ 4, T3 (4097, 6144, 1, 1, 1, 1)
C3/ 4, T4 (6144, 8192, 1, 1, 1, 1)
TDI Mod e Reverse Direction right to
left read ou t
C1/ 2, T1 (8192, 7169, -1, 1, 1, 1) C1/ 2,
T2 (7168, 6145, -1, 1, 1, 1)
C1/ 2, T3 (6144, 5121, -1, 1, 1, 1)
C1/ 2, T4 (5120, 4097, -1, 1, 1, 1)
C1/ 2, T5 (4096, 3073, -1, 1, 1, 1)
Summary of Contents for DALSA HS-80-08k40-xx-R
Page 16: ...Piranha HS xx RoHS User Manual 03 032 20013 03 Teledyne DALSA 16 ...
Page 84: ...Piranha HS xx RoHS User Manual 03 032 20013 03 Teledyne DALSA 84 ...
Page 108: ...Piranha HS xx RoHS User Manual 03 032 20013 03 Teledyne DALSA 108 ...
Page 110: ...Piranha HS xx RoHS User Manual 03 032 20013 03 Teledyne DALSA 110 ...
Page 116: ...Piranha HS xx RoHS User Manual 03 032 20013 03 Teledyne DALSA 116 ...
Page 120: ...Piranha HS xx RoHS User Manual 03 032 20013 03 Teledyne DALSA 120 ...