Programming Manual
–
T3AWG3K-C Series Arbitrary Waveform Generator
True-Arb Operating Mode
138
Before running the VI you have to select the AWG-3000 resource in the VISA resource name
control.
•
Run the VI
and press the “START AWG” button to start the generation.
•
The Analog Channel Settings section lets you to change on the fly the Amplitude Scale,
the Base Line Offset, the Skew, the Polarity and the Output Impedace parameters.
Select the Channel and press the Apply Changes button to confirm the changes.
•
You can press the CH OFF/ON button to enable or disable the analog channel.
The entire sequence w
ill be repeated continuously until you press again the “START AWG”
button.
5.2.2
Burst Mode
Double click on the project tree to launch the
Active Technologies AWG3000 3-Entry
Sequencer in Burst mode.vi
example