background image

 

VUE TZ20-R User Manual

 

Equipment described herein is subject to US export regulations and may require a license prior to export. Diversion contrary to US law is 
prohibited. Imagery for illustration purposes only. Specifications are subject to change without notice.  Rev. 100. 
© 2021 Teledyne FLIR LLC, Inc. Approved for public release. Teledyne FLIR Approved [FLIRGTC-SBA-007]. All rights reserved.

 

          

8

4.5 Zoom 

 

The FLIR Vue TZ20-R is capable of up to 20x thermal zoom.  The user can maintain a wide 
FOV to cover a large area quickly and then zoom in on targets of interest when desired. 
Pressing the zoom icon allows the user to select 1x, 5x, 10x, and 20x zoom, is calculated 
based on the wide horizontal field of view (HFOV), or WFOV Boson.  Zoom level 1x utilizes a 
wide, 95° HFOV, 640x512 resolution Boson.  This is referred to as the NFOV Boson.  Zoom 
levels 5x, 10x, and 20x utilize a narrow, 18° HFOV, 640x512 resolution Boson.  Zooming 
from 1x to 5x is an optical zoom, unique to the TZ20-R and places over 327,000 pixels on 
target at both levels. Zooming 5x, 10x, and 20x is a digital zoom.  All four zoom levels place 
four times more pixels on target versus pure digital zoom payloads using the same starting 
HFOV.  TIFF images are saved without the zoom applied.   JPEG and MOV are saved with 
zoom and colorized.  The Vue TZ20-R should be at least 50 feet from the target when using 
the 20X zoom setting to maximize focus.  At the 5X zoom setting, the minimum distance to 
target is 5 feet. 

 

FIGURE 6.  1X, 5X, 10X, AND 20X ZOOM LEVELS

    

4.6  Radiometry          

 

 

 

 

                                                   

The TZ20-R is equipped with a variety of radiometric features that can be enabled by the 
pilot.  These include a spot meter measurement, region of interest (ROI) measurement 
boxes that display the hottest, coolest, and average temperature of all pixels within the ROI, 
and hot or cold isotherms.  Press the radiometry icon to select radiometric settings.  It is 
recommended that new users operate the TZ20-R with its factory default settings for 
radiometry.  The Vue TZ20-R has a humidity and temperature sensor that is used to 
calculate the effect of atmospheric absorption for radiometry.  The Vue TZ20-R includes 
settings to adjust radiometric calculations based on scene and atmospheric 
conditions.  These parameters can also be adjusted for radiometric JPEG files in FLIR 

Summary of Contents for Flir Vue TZ20-R

Page 1: ...to US law is prohibited Imagery for illustration purposes only Specifications are subject to change without notice Rev 100 2021 Teledyne FLIR LLC Inc Approved for public release Teledyne FLIR Approved...

Page 2: ...or Palettes 7 4 5 Zoom 8 4 6 Radiometry 8 4 7 Settings 12 5 SD CARDS 13 5 1 File Naming Convention 13 5 2 Tested Micro SD Cards 14 6 RECORDING 15 7 SETTINGS 16 7 1 Image format 16 7 2 Video format 17...

Page 3: ...arm and other industrial inspectors can zoom into objects of interest identify them with unmatched clarity and take and record radiometric temperature measurements all from a safe standoff distance Em...

Page 4: ...mbal into gimbal mount on airframe 2 Rotate the Skyport connector to the unlocked position and completely insert into the airframe gimbal mount 3 Rotate the Skyport connector to the locked position to...

Page 5: ...C SBA 007 All rights reserved 5 3 DJI PILOT APP INSTALLATION The Matrice aircraft often comes with a controller with the DJI Pilot App installed If an additional Android based device is required pleas...

Page 6: ...the DJI Pilot app In the main screen users have the option to toggle between recording modes through the Menu and adjust operational parameters including Flat Field Correction FFC AGC color palette z...

Page 7: ...tional conditions The Vue TZ20 R is always in auto FFC mode but a manual trigger can be initiated by pressing the FCC icon Note that when a FFC is executed the live image will be paused momentarily 4...

Page 8: ...and 20x is a digital zoom All four zoom levels place four times more pixels on target versus pure digital zoom payloads using the same starting HFOV TIFF images are saved without the zoom applied JPEG...

Page 9: ...OT METER DISPLAYED ON USER INTERFACE 4 6 2 Regions of Interest ROI There are two ROI options Frame and Center Frame defines the ROI as the full view as displayed on the user interface Center creates a...

Page 10: ...rt Diversion contrary to US law is prohibited Imagery for illustration purposes only Specifications are subject to change without notice Rev 100 2021 Teledyne FLIR LLC Inc Approved for public release...

Page 11: ...herms are useful in helping to quickly identify areas or objects of interest within the scene and can be used for inspection search and rescue and more FIGURE 9 5X ZOOM AND ABOVE ISOTHERM HIGHLIGHTS P...

Page 12: ...S law is prohibited Imagery for illustration purposes only Specifications are subject to change without notice Rev 100 2021 Teledyne FLIR LLC Inc Approved for public release Teledyne FLIR Approved FLI...

Page 13: ...er a protective cover This port is intended for storing logs by DJI and will NOT save data from the Vue TZ20 R FIGURE 11 INSERT MICRO SD CARD 1 AND 2 TO OPERATE VUE TZ20 R 5 1 File Naming Convention F...

Page 14: ...ved for public release Teledyne FLIR Approved FLIRGTC SBA 007 All rights reserved 14 5 2 Tested Micro SD Cards The validated Micro SD cards that are supported by the Vue TZ20 R are shown below Working...

Page 15: ...n be saved in TIFF and R JPEG format TIFF files contain raw data from the Boson thermal camera Both WFOV and NFOV images are saved R JPEG contains a colorized image of what is displayed on screen Stan...

Page 16: ...en tap the payload icon User can directly access the payload settings by tapping the Payload Settings Icon in the quick menu In this menu the user can modify various capture settings The camera will b...

Page 17: ...ameras Hot Low gain mode Appropriate range for higher temperatures scenes 40 C to 550 C Normal High gain mode Appropriate range for lower temperatures scenes 25 C to 135 C 7 5 AGC Region of interest A...

Page 18: ...y true when using the 5x 10x or 20x zoom feature Ensure objects are at least 20 feet 6 m from the Vue TZ20 R for best zoomed focus Thermal image quality is best when viewing high contrast scenes where...

Page 19: ...x optical WFOV NFOV 4x digital Effective zoom 1x 95 5x 10x 20x 4 5 Ground Control DJI Pilot App Airframe Compatibility DJI V2 Matrice 200 series and Matrice 300 Storage 2 Micro SD cards Streaming Vide...

Page 20: ...repaired or modified in any manner by anyone other than Teledyne FLIR or Teledyne FLIR s authorized designee Defects due to normal wear and tear Customer s failure to properly store install operate or...

Page 21: ...solid green when the Vue TZ20 R is powered up and ready to record stream Recording Green flashing slow The LED appears flashing green when streaming video is being recorded to the storage Warning Ora...

Page 22: ...the Vue TZ20 R unusable 4 The Vue TZ20 R LED will blink purple during the upgrade 5 The Vue TZ20 R will automatically power cycle The LED will flash orange for power up then resume a standard LED oper...

Page 23: ...e when power cycling the airframe Vue TZ20 R while the RC and app are still active When this occurs restart the DJI Pilot app Power cycling the controller will also resolve the same issue but requires...

Page 24: ...eserved 24 12 SUPPORT AND ADDITIONAL RESOURCES Visit the OEM support portal at flir custhelp com Click Ask a Question and fill out the form to reach a product specialist FIGURE 14 VUE TZ20 R SUPPORT I...

Reviews: