2 – Installation
2-2
© Teledyne Limited
DPN 402197 Issue 7.1
❐
1 x 350 coil tester
❐
Assorted fasteners
Case 3: SDC10 (optional) - see separate manual for scope of supply
Case 4: Altimeter (optional)
❐
1 x ALT-250 altimeter
❐
1 x ALT-250 cable (3m)
Loose:
❐
1 x 350 coil mounting bar
2.2 Physical Installation
NOTE
For information on installing the topside computer refer to its dedicated user man-
ual.
2.2.1 SEP
NOTE
Do not open the SEP unless you need to change the communication method.
There is a nylon mounting block attached to the SEP. This block provides a safe and secure method to
mount the housing to the ROV frame.
CAUTION
Do not attempt to secure the SEP housing directly to the ROV framework without
using the mounting block. Omitting the mounting block may cause damage to the
surface of the housing, leading to corrosion.
The mounting block has machined slots that allow you to strap the complete housing and block
assembly firmly to the ROV frame. Stainless steel strapping is ideal for this purpose (see
It is safe to mount the SEP in any orientation.
Mount the SEP housing according to the following guidelines:
❐
Eliminate any possibility of snagging or damage to the SEP housing by installing it inside the
outer limits of the ROV frame.