3 – Operating software
3-4
© Teledyne Limited
DPN 402197 Issue 7.1
Figure 3-2: System Configuration Wizard - Summary
DeepView will now be configured to operate with the 350 system.
Before clicking on ‘Finish’ you have tick options to select:-
❐
Show the pre-dive checklist when the System Configuration Window is closed.
❐
Whether the System Configuration Wizard runs when DeepView starts.
NOTE
If the box is checked, the System Configuration Wizard will be run when
DeepView starts. If the box is not checked and if a configuration file is available,
the configuration file will be used to configure DeepView.
DeepView stores the configuration details automatically in an initialisation file when DeepView is
closing down. This allows the system to establish the same configuration when you next power-on the
topside computer, provided it recognises the data format arriving from the SEP as being compatible
with the stored configuration details. This means that you should power-on the SEP before you launch
DeepView.
3.2.3 System Parameters
3.2.3.1 Tone frequency
Set this value to the same frequency as that present on the cable. The range is from zero to 200Hz. An
error of ±1Hz or more in setting the frequency could cause the system to reject the tone.
You may improve the performance of the System in the presence of background noise by using the
Spectrum Analyser (see
) display to select a suitable tone frequency.