background image

©

                                                                                                            

Page 

2

 of 

28

 

Description 

Power-Over-Ethernet (POE) Box 

Sonar to Surface Cable (25 ft.) 

Cable Whip (4 ft.) 

Ethernet Cable (7 ft.) 

ProViewer CD 

Quickstart Guide 

User Handbook 

Rugged Carry Case 

 

 

 

 

 

 

Summary of Contents for P series

Page 1: ...Part Number 202914 00 Revision I January 2016 2016 Teledyne BlueView All rights reserved All product names are trademarks of their respective companies ...

Page 2: ... Page 2 of 28 Description Power Over Ethernet POE Box Sonar to Surface Cable 25 ft Cable Whip 4 ft Ethernet Cable 7 ft ProViewer CD Quickstart Guide User Handbook Rugged Carry Case ...

Page 3: ... Page 3 of 28 2 6 6 7 7 7 8 8 8 9 9 10 11 11 12 12 12 14 15 15 15 15 16 17 17 18 19 19 19 20 ...

Page 4: ... Page 4 of 28 21 21 22 24 24 25 25 26 27 ...

Page 5: ... Page 5 of 28 ...

Page 6: ... Page 6 of 28 ...

Page 7: ... Page 7 of 28 ...

Page 8: ... Page 8 of 28 ...

Page 9: ... Page 9 of 28 ...

Page 10: ... Page 10 of 28 Connect ...

Page 11: ... Page 11 of 28 ...

Page 12: ... Page 12 of 28 ...

Page 13: ... Page 13 of 28 RJ11 Connector To the Sonar Power Cable Plug PC link VDSL link to sonar Power ...

Page 14: ... Page 14 of 28 Connect ...

Page 15: ... Page 15 of 28 Top Top Bottom Bottom ...

Page 16: ... Page 16 of 28 Target Depth ft 0 10 20 30 40 60 80 Approx Tilt Angle Deg 0 3 8 10 10 15 20 ...

Page 17: ... Page 17 of 28 ...

Page 18: ... Page 18 of 28 ...

Page 19: ... Page 19 of 28 ...

Page 20: ...t repair or disable then enable You can also simply restart the computer or cycle the power on the sonar IP subnet masks don t match Make sure the subnet mask is the same on both PC and sonar For the factory default Class C network configuration the subnet mask is 255 255 255 0 The 255 defines the network portion of the IP address The 0 defines the device portion of the IP address IP network addre...

Page 21: ... long range settings directly cause slow updates Reduce the Range Stop distance to increase the update rate GUI window size The larger the displayed sonar image the longer it takes for the ProViewer software to construct the image To increase the image display update rate decrease the size of the sonar image display window by grabbing one of sides or corner of the GUI and dragging it towards the c...

Page 22: ... ft 100m 328 ft 100m 328 ft 900kHz 8m 26 2 ft 2250kHz Beam Width 1º x 10º 1º x 10º 1º x 10º 1º x 20º 1º x 20º 1º x 20º 1º x 20º Number of Beams 256 512 768 256 512 768 256 Beam Spacing 0 18º 0 18º 0 18º 0 18º 0 18º 0 18º 0 18º Range Resolution 2 in 2 in 2 in 1 in 1 in 1 in 1 in 900kHz 0 4 in 2250kHz Update Rate Up To 12 Hz Up To 12 Hz Up To 12 Hz Up To 15 Hz Up To 15 Hz Up To 15 Hz Up to 15 Hz ...

Page 23: ...900 kHz 900 kHz 2 25 MHz Weight In Air 5 7 lb 8 6 lb 8 6 lb 5 0 lb 5 5 lb 5 5 lb 6 0 lb Weight In Water 1 4 lb 2 9 lb 2 9 lb 1 1 lb 1 4 lb 1 4 lb 1 5 lb Depth Rating 1 000m 1 000 m 1 000 m 1 000m 1 000m 1 000m 300m Size 8 9 in x 7 0 in 8 9 in x 7 0 in 8 9 in x 7 0 in 11 3 in x 5 in O D 11 3 in x 5 in O D 11 3 in x 5 in 8 3 in x 5 0 in ...

Page 24: ... Page 24 of 28 ...

Page 25: ... Page 25 of 28 ...

Page 26: ... Page 26 of 28 Units Inches ...

Page 27: ...MKS10 10 Pin 1 ORANGE WHITE Rx 1 2 ORANGE Rx 2 3 GREEN WHITE Tx 3 4 BLUE 12 48V 4 5 BLUE WHITE 12 48V 5 6 GREEN Tx 6 7 BROWN WHITE DC Return 7 8 BROWN DC Return 8 9 N A No Connection 9 10 N A No Connection 10 Impulse Connector Part BlueView 200015 01 Mfr MKS 310 CPP RA ...

Page 28: ...DUCTOR COLOR FUNCTION BR8 8 Pin 1 ORANGE WHITE Rx 1 2 ORANGE Rx 2 3 GREEN WHITE Tx 3 4 BLUE BLUE WHITE 12 48V 4 5 N C YELLOW N A 5 6 GREEN Tx 6 7 BROWN BROWN WHITE DC Return 7 8 N C YELLOW WHITE N A 8 RJ45 Connector BURTON Connector Part 5501 1508 ...

Reviews: