ProEM System Manual
Issue 3
Sealed Chamber Integrity Limited 12 Month Warranty
Teledyne Princeton Instruments warrants the sealed chamber integrity of all our products
for a period of twelve (12) months after shipment. If, at anytime within twelve (12) months
from the date of delivery, the detector should experience a sealed chamber failure, all
parts and labor needed to restore the chamber seal will be covered by us.
Open chamber
products carry NO WARRANTY TO THE CCD IMAGING DEVICE, EXPRESSED OR IMPLIED.
Responsibility for shipping charges is as described above under our Basic Limited One (1)
Year Warranty.
Vacuum Integrity Limited 12 Month Warranty
Teledyne Princeton Instruments warrants the vacuum integrity of "Non-XP" style
detectors (do not have all metal seals) for a period of up to twelve (12) months from the
date of shipment. We warrant that the detector head will maintain the factory-set
operating temperature without the requirement for customer pumping. Should the
detector experience a Vacuum Integrity failure at anytime within twelve (12) months from
the date of delivery all parts and labor needed to restore the vacuum integrity will be
covered by us. Responsibility for shipping charges is as described above under our Basic
Limited One (1) Year Warranty.
Image Intensifier Detector Limited One Year Warranty
All image intensifier products are inherently susceptible to Phosphor and/or
Photocathode burn (physical damage) when exposed to high intensity light. Teledyne
Princeton Instruments warrants, with the exception of image intensifier products that are
found to have Phosphor and/or Photocathode burn damage (which carry NO
WARRANTIES EXPRESSED OR IMPLIED,) all image intensifier products for a period of one
(1) year after shipment.
Refer to additional Limited One (1) year Warranty terms and
conditions above, which apply to this warranty.
Responsibility for shipping charges is as
described above under our Basic Limited One (1) Year Warranty.
X-Ray Detector Limited One Year Warranty
Teledyne Princeton Instruments warrants, with the exception of CCD imaging device and
fiber optic assembly damage due to X-rays (which carry NO WARRANTIES EXPRESSED OR
IMPLIED,) all X-ray products for one (1) year after shipment.
Refer to additional Basic
Limited One (1) year Warranty terms and conditions above, which apply to this warranty.
Responsibility for shipping charges is as described above under our Basic Limited One (1)
Year Warranty.
Software Limited Warranty
Teledyne Princeton Instruments warrants all of our manufactured software discs to be
free from substantial defects in materials and/or workmanship under normal use for a
period of one (1) year from shipment. Teledyne Princeton Instruments does not warrant
that the function of the software will meet your requirements or that operation will be
uninterrupted or error free. You assume responsibility for selecting the software to
achieve your intended results and for the use and results obtained from the software. In
addition, during the one (1) year limited warranty. The original purchaser is entitled to
receive free version upgrades. Version upgrades supplied free of charge will be in the form
of a download from the Internet. Those customers who do not have access to the Internet
may obtain the version upgrades on a CDROM from our factory for an incidental shipping
and handling charge.
Refer to Item 12 in
of this warranty for more
information.
Summary of Contents for ProEM Series
Page 1: ...www princetoninstruments com ProEM System Manual 4411 0126 Issue 3 September 26 2019 ...
Page 10: ...10 ProEM System Manual Issue 3 This page is intentionally blank ...
Page 16: ...16 ProEM System Manual Issue 3 This page is intentionally blank ...
Page 30: ...30 ProEM System Manual Issue 3 This page is intentionally blank ...
Page 50: ...50 ProEM System Manual Issue 3 This page is intentionally blank ...
Page 88: ...88 ProEM System Manual Issue 3 This page is intentionally blank ...
Page 114: ...114 ProEM System Manual Issue 3 This page is intentionally blank ...
Page 122: ...122 ProEM System Manual Issue 3 Figure 7 8 LightField Settings 4411 0126_0078 ...
Page 136: ...136 ProEM System Manual Issue 3 This page is intentionally blank ...
Page 146: ...146 ProEM System Manual Issue 3 This page is intentionally blank ...
Page 152: ...152 ProEM System Manual Issue 3 This page is intentionally blank ...
Page 161: ...This page is intentionally blank ...