GETTING STARTED
23
Configuration Table
Please use the configuration settings listed below when applying
the configuration settings.
Normal Function
Settings
Setting Setting Range
Output ON delay time
F-01
0.00s-99.99s
Output OFF delay time F-02
0.00s-99.99s
V-I mode slew rate select F-03
0 = CV high speed priority (CVHS)
1 = CC high speed priority (CCHS)
2 = CV slew rate priority (CVLS)
3 = CC slew rate priority (CVLS)
Rising voltage slew rate F-04
0.001-0.06V/msec (T3PS062001P)
0.001-0.4V/msec (T3PS40381P)
0.001-0.6V/msec (T3PS60251P)
Falling voltage slew rate F-05
0.001-0.06V/msec (T3PS062001P)
0.001-0.4V/msec (T3PS40381P)
0.001-0.6V/msec (T3PS60251P)
Rising current slew rate F-06
0.001-2A/msec (T3PS062001P)
0.001-0.38A/msec (T3PS40381P)
0.001-0.25A/msec (T3PS60251P)
Falling current slew rate F-07
0.001-2A/msec (T3PS062001P)
0.001-0.38A/msec (T3PS40381P)
0.001-0.25A/msec (T3PS60251P)
Internal resistance
setting
F-08
0-0.03
Ω
(T3PS062001P)
0-1.053
Ω
(T3PS40381P)
0-2.4
Ω
(T3PS60251P)
Bleeder circuit control
F-09
0 = OFF, 1 = ON, 2 = AUTO
Buzzer ON/OFF control F-10
0 = OFF, 1 = ON
OCP Delay Time
F-12
0.1-2.0 sec
Current Setting Limit
(I-Limit)
F-13
0 = OFF, 1 = ON
Voltage Setting Limit
(V-Limit)
F-14
0 = OFF, 1 = ON