REMOTE CONTROL
31
UART Remote Interface
Configure UART
Overview
The T3PS uses the IN & OUT ports for UART
communication coupled with RS232 or RS485
adapters.
The pin outs for the adapters are shown below.
RS232 cable with
DB9 connector
DB-9 Connector
Remote IN Port
Remarks
Pin No.
Name
Pin No.
Name
Housing Shield
Housing Shield
2
RX
7
TX
Twisted
pair
3
TX
8
RX
5
SG
1
SG
5 1
9 6
1 8
RS485 cable with
DB9 connector
DB-9 Connector
Remote IN Port
Remarks
Pin No.
Name
Pin No.
Name
Housing Shield
Housing Shield
9
TXD -
6
RXD -
Twisted
pair
8
TXD +
3
RXD +
1
SG
1
SG
5
RXD -
5
TXD -
Twisted
pair
4
RXD +
4
TXD +