REMOTE CONTROL
119
3= CH3 (for T3PS43203P only)
4= CH4 (for T3PS43203P only)
<NR2>
Decimal number, range 0-6.200A
Example
ISET1:2.234
Sets the CH1 output current to 2.234A.
:SOURce[1|2|3|4]:CURRent?
Description
Queries the current limit level.
Example
:SOURce2:CURRent?
Queries the current limit level on CH2.
ISET<X>?
Description
Returns the output current setting.
Parameter
<X>
1= CH1
2= CH2
3= CH3 (for T3PS43203P only)
4= CH4 (for T3PS43203P only)
Example
ISET1?
Returns the CH1 output current setting.
:SOURce[1|2|3|4]:CURRent[:LIMit]:STATe?
Description
Queries the current limit state. Returns CV if the
current limit has not been reached, returns CC if
the current limit has been reached.
Example
:SOURce2:CURRent:STATe?
Queries the current limit state of CH2.
Summary of Contents for T3PS13206P
Page 1: ... ...
Page 106: ...T3PSX3200P Series User Manual 106 Register Commands OPC 187 OPC 187 ...
Page 177: ...REMOTE CONTROL 177 Example SAV 1 Recalls the setting stored in memory 2 STATE02 ...
Page 185: ...REMOTE CONTROL 185 Example STB Returns 81 if the status byte register is set to 0101 0001 ...
Page 196: ...T3PSX3200P Series User Manual 196 Between chassis and DC power cord 30MΩ or above DC 500V ...
Page 197: ... 0 0 0 1 2 3 4 5 6 7 8 8 9 3 3 3 45 6 990 0 0 9 0 0 0 9 0 0 0 0 9 7 7 88 8 1 931711 RevB ...