T3PSX3200P Series User Manual
174
2: 9600bps
Example
BAUD0
Sets the baud rate to 115200bps
Note
Default baud rate is 9600bps
HELP?
Description
Shows the Simple command list.
Return Parameter
ISET<x>:<NR2> Sets the value of current.
VSET<x>:<NR2> Sets the value of voltage.
ISET<x>?
Return the value of current.
VSET<x>?
Return the value of voltage.
IOUT<x>?
Returns actual output current.
VOUT<x>?
Returns actual output voltage.
TRACK<NR1> Sets the output of the power
supply working on
independent or tracking mode.
BAUD<NR1>
Set the value of baud rate.
RCL<NR1>
Recall the setting data from the
memory which previous saved.
SAV<NR1>
Saves the setting data to
memory.
BEEP<Boolean> Sets the BEEP state on or off.
OUT<Boolean> Sets the output state on or off.
LOCAL
Return to local mode
REMOTE
Return to remote mode
*IDN?
Returns instrument
identification.
ERR?
Returns instrument error
messages.
STATUS?
Returns the power supply state.
Summary of Contents for T3PS13206P
Page 1: ... ...
Page 106: ...T3PSX3200P Series User Manual 106 Register Commands OPC 187 OPC 187 ...
Page 177: ...REMOTE CONTROL 177 Example SAV 1 Recalls the setting stored in memory 2 STATE02 ...
Page 185: ...REMOTE CONTROL 185 Example STB Returns 81 if the status byte register is set to 0101 0001 ...
Page 196: ...T3PSX3200P Series User Manual 196 Between chassis and DC power cord 30MΩ or above DC 500V ...