T3PSX3200P Series User Manual
60
Range: 1s – 300s
Patterm
Set the initial status of initial group. 01
Patt: start from Off; 10Patt: start from
On
Time set
It is used to generally set the pattern of
time change. Model is for the changes
covering fix (FixTime), increase
(Increase) and decline (Decline). Base
Time is for setting time of initial Group.
Step is for setting time interval of
neighboring Group.
Parameter
Setting
No.
Under the Delay function, press the F2
(Edit) button followed by selecting the
F1 (No.). The setting on LCD is
activated and appears in red font color
. Use number pad to set
the parameters directly and then press
the F1 (Done) button to confirm; or use
arrow keys along with scroll wheel to
complete the setting.
State
Under the Delay function, press the F2
(Edit) button, and then the F2 (State)
button followed by selecting F1 (On),
F2 (Off) or F3 (Inverted) to set output
On/Off status of each group.
Time
Under the Delay function, press the F2
(Edit) button followed by selecting the
F3 (Time). The setting on LCD is
activated. Use number pad to set the
parameters directly and then press the
F1 (Second) button to confirm; or use
arrow keys along with scroll wheel to
complete the setting.
Pattern
Under the Delay function, press the F2
(Edit) button followed by selecting F4
(Pattern), and then set up via F1
Summary of Contents for T3PS13206P
Page 1: ... ...
Page 106: ...T3PSX3200P Series User Manual 106 Register Commands OPC 187 OPC 187 ...
Page 177: ...REMOTE CONTROL 177 Example SAV 1 Recalls the setting stored in memory 2 STATE02 ...
Page 185: ...REMOTE CONTROL 185 Example STB Returns 81 if the status byte register is set to 0101 0001 ...
Page 196: ...T3PSX3200P Series User Manual 196 Between chassis and DC power cord 30MΩ or above DC 500V ...
Page 197: ... 0 0 0 1 2 3 4 5 6 7 8 8 9 3 3 3 45 6 990 0 0 9 0 0 0 9 0 0 0 0 9 7 7 88 8 1 931711 RevB ...