T3PSX3200P Series User Manual
74
F4(Track Mode) sets tracking mode of CH1/CH2
F3
Sensitivity
Set sensitivity of trigger: High/Middle/Low
F4
F5
F6
Return
F5 (More) under Output Mode setting:
Key
Function
Operation Result
F1
Condition
Set response type: F1(Output), F2 (Voltage), F3
(Current), F4 (Power), F5 (Auto)
F2
Polarity
Set the polarity of output signal
F3
F4
F5
State Out.
Enable or disable the state output
F6
Return
Description
Operation
Press the System key on control panel. Select the
F1 (Interface) function followed by pressing the
F5 (Control I/O) button to enter the setting of
external I/O.
Press the F1 (Data Line) button. Select required
data line from D0 through D5: F1(D0), F2(D1) ,
F3(D2) , F4(D3) , F5(D4).
Press the F2 (Enable) button to set this terminal as
input or output function. This button enables
Trigger in or Trigger out to be selected in turn.
Press the F3 (Mode) button to set this terminal as
input or output function. This button enables
Input Mode or Output Mode to be selected in
turn.
Press the F4 (Channel) button to activate the
Summary of Contents for T3PS13206P
Page 1: ... ...
Page 106: ...T3PSX3200P Series User Manual 106 Register Commands OPC 187 OPC 187 ...
Page 177: ...REMOTE CONTROL 177 Example SAV 1 Recalls the setting stored in memory 2 STATE02 ...
Page 185: ...REMOTE CONTROL 185 Example STB Returns 81 if the status byte register is set to 0101 0001 ...
Page 196: ...T3PSX3200P Series User Manual 196 Between chassis and DC power cord 30MΩ or above DC 500V ...
Page 197: ... 0 0 0 1 2 3 4 5 6 7 8 8 9 3 3 3 45 6 990 0 0 9 0 0 0 9 0 0 0 0 9 7 7 88 8 1 931711 RevB ...