Quick Start 9
1.6 Output Check
The output check includes voltage check of all channels with no load, and current
check with a short circuit so as to make sure that the instrument is working
correctly.
Voltage Output Check
1. Within no load, turn on the power, and make sure the current setting
values of all channels are not zero.
2. Turn on CH1 and CH2 outputs, and check that the instrument is working
in constant voltage mode (CV on the display of each channel). Check
whether the output voltage value can be adjusted from 0V to 32V.
Current Output Check
1. Turn on the power, and make sure the current setting values of all
channels are not zero.
2. Use an insulated wire to connect the positive and negative terminal of
CH1/CH2.
3. Turn on CH1/CH2 and check that the instrument is working in
constant current mode. (CC on the display of each channel). Check
whether the current value could be adjusted from 0A to 3.2A.