2.5 CH1 / CH2 Parallel Mode
In parallel mode, CH1 and CH2 are linked internally to one channel, which is
controlled by CH1. Its output current value is twice as much as that of the
single channel current value.
Output rating
0~32V / 0~6.4A
Operation:
1. Press the “Para” button to start Parallel mode, the indicator light turns
on immediately and the logo “
”
display at the top of screen.
2. Connect the load to the positive and negative terminal of CH1.
3. Set voltage and current value:
a) Press “1” button to select the channel 1
b) Use the direction button to move the cursor to the desired
parameter (voltage, current),
c) Press “Fine” to select the digit position and then revolve the
multi-function knob to change the corresponding parameter.
4. Press “on/off” button corresponding CH1 to turn on the output.
Note:
You can identify if the PSU is in “CC” or ”CV” mode by referring to the
indicator light of CH1 / CH2. (red indicates CV, yellow indicates CC).
In parallel mode, CH2 only works in CC mode.
16 Quick Start