5-1
TIENet™ 360 LaserFlow™
Velocity Sensor
Section 5 Maintenance and Optional Kits
5.1 Maintenance
The following tables are recommended maintenance checks to
ensure proper operation. As site conditions may vary, increase
the frequency of inspections as needed.
Table 5-1 Recommended Maintenance (Accessible Locations)
Action
Recommended
Frequency
Location
Check Ultrasonic level sensor (built-in or remote) for obstructions
(e.g., spider webs, debris)
Monthly
On-site
Check Horn for obstructions (e.g., spider webs, debris)
Monthly
On-site
Check 350 Area Velocity sensor (if applicable) for debris
Monthly or following
surcharge event
On-site
Ensure suitable alignment - check x-axis (roll) and y-axis (pitch)
Weekly
Via Flowlink application or
Signature™ flow meter
Check Doppler Power and assess historical trend
Weekly
Via Flowlink application or
Signature™ flow meter
Check Ultrasonic Signal and assess historical trend
Weekly
Via Flowlink application or
Signature™ flow meter
Table 5-2 Recommended Maintenance (Difficult-to-Access Locations)
Action
Recommended
Frequency
Location
Check Ultrasonic level sensor (built-in or remote) for obstructions
(e.g., spider webs, debris)
Every 6 months or
following surcharge
event
On-site
Check Horn for obstructions (e.g., spider webs, debris)
Every 6 months or
following surcharge
event
On-site
Check 350 Area Velocity sensor (if applicable) for debris
Every 6 months or
following surcharge
event
On-site
Ensure suitable alignment - check x-axis (roll) and y-axis (pitch)
Weekly
Via Flowlink application or
Signature™ flow meter
Check Doppler Power and assess historical trend
Weekly
Via Flowlink application or
Signature™ flow meter
Check Ultrasonic Signal and assess historical trend
Weekly
Via Flowlink application or
Signature™ flow meter
Summary of Contents for TIENet 360 LaserFlow Ex
Page 2: ......
Page 4: ......
Page 10: ...TIENet 360 LaserFlow Velocity Sensor Safety viii ...
Page 54: ...TIENet 360 LaserFlow Velocity Sensor Section 2 Preparation and Installation 2 32 ...
Page 90: ...TIENet 360 LaserFlow Velocity Sensor Section 4 Setup with 2160 LaserFlow Module 4 20 ...
Page 102: ...TIENet 360 LaserFlow Velocity Sensor Appendix A Replacement Parts A 2 A 2 LaserFlow Sensor ...
Page 103: ...TIENet 360 LaserFlow Velocity Sensor Appendix A Replacement Parts A 3 ...
Page 104: ...TIENet 360 LaserFlow Velocity Sensor Appendix A Replacement Parts A 4 ...
Page 105: ...TIENet 360 LaserFlow Velocity Sensor Appendix A Replacement Parts A 5 ...
Page 106: ...TIENet 360 LaserFlow Velocity Sensor Appendix A Replacement Parts A 6 ...
Page 107: ...TIENet 360 LaserFlow Velocity Sensor Appendix A Replacement Parts A 7 ...
Page 109: ...TIENet 360 LaserFlow Velocity Sensor Appendix A Replacement Parts A 9 ...
Page 111: ...TIENet 360 LaserFlow Velocity Sensor Appendix A Replacement Parts A 11 ...
Page 132: ...TIENet 360 LaserFlow Velocity Sensor D 6 ...
Page 136: ......
Page 138: ...Warranty ...
Page 140: ......