Revision Date | July 10, 2017 || Document Number | UM-E71-308-01 || Rev C
40 of 48
Table 13: Qualification Test Matrix - EMI
Test Description
Test Spec
Test Section / Category
Magnetic Effect
D0-160G
15.0, CAT Z
Power Input – Normal Operating
Individual Phase Voltage
787B3-0147
DO-160G
3.3.2.1 B1.1a
16.5.1.1 Cat A (CF)
AC Voltage Modulation
787B3-0147
DO-160G
3.3.2.1 B1.5a
16.5.1.2 Cat A (WF)
Voltage Waveform – Total Harmonic Content
787B3-0147
DO-160G
3.3.2.1 B1.6.1a
16.5.1.8.2 Cat A (WF)
Voltage Waveform – Individual Harmonic Content
787B3-0147
3.3.2.1 B1.6.2a
Voltage Waveform – DC Content
787B3-0147
DO-160G
3.3.2.1 B1.6.3a
16.5.1.7 Cat A (WF)
Voltage Waveform – Crest Factor
787B3-0147
Not Required
Steady State Frequency
787B3-0147
Not Required
Normal Voltage Transients
787B3-0147
3.3.2.1 B2.1a
Frequency Modulation (ac)
DO-160G
16.5.1.3, CAT A(CF)
Momentary Power Interruptions (ac)
787B3-0147
DO-160G
3.3.2.1.1, Table 3.3.2-3B
16.5.1.4, CAT A(CF)
Normal Surge Voltage (ac)
DO-160G
16.5.1.5.1, CAT A(CF)
Normal Frequency Transients (ac)
DO-160G
16.5.1.5.2
Frequency Variations – Maximum Ramp Rate
787B3-0147
3.3.2.1 B2.3.1a
Frequency Variations – Frequency Transients
787B3-0147
Not Required
Multiple Stroke Power Interrupts
787B3-0147
3.3.2.1 B2.4a
Power Input – Abnormal Operating
Individual Phase Voltage
787B3-0147
DO-160G
3.3.2.2 B3.1a
16.5.2.1 Cat A (CF)
Abnormal Voltage Transients
787B3-0147
DO-160G
3.3.2.2 B4.1a
16.5.2.2 Cat A (CF)
Abnormal Frequency Transients
DO-160G
16.5.2.3.2b Cat A (CF)
Frequency Variation – Maximum Ramp Rate
787B3-0147
3.3.2.2 B4.2.1a
Frequency Variation – Frequency Transients
787B3-0147
3.3.2.2 B4.2.2a
Abnormal DC Content
787B3-0147
3.3.2.2 B4.3a
Maximum Power Demand (Inrush)
787B3-0147
3.4.3.1 B1
Load Switching Transients
787B3-0147
3.4.3.3 B1
Load Demand Variation
787B3-0147
D6-44588
3.4.3.4
3.4.5.4
Current Harmonics
787B3-0147
Not Required
(1)
Power Factor
787B3-0147
3.4.3.7B
Input Capacitance
787B3-0147
3.4.3.8B