Programmable Sweep Instruction Manual
CONFIGURATION
telemark.com
39 of 58
Rev 1.0.0
5.8 Pattern Configuration Setup
5.8.1 Triangle
Figure 5-15, Setup Pattern, Triangle
Freq Lat
–
Frequency Latitudinal 0.1Hz to 80Hz
Freq Long
–
Frequency Longitudinal, 0.1Hz to 80Hz
Amp Lat
–
Amplitude Latitudinal, 20-100% of configured maximum pocket
Amp Long
- Amplitude Longitudinal, 20-100% of configured maximum pocket
LDC Tail
–
Display of the history of the pattern, 10 to 1000
Shift Menu
Phase Lat
–
Relative phase shift of the latitudinal pattern, -359 degrees to 359 degrees
Phase Long
–
Relative phase shift of the longitudinal pattern, -359 degrees to 359
degrees
Rotation
–
Rotation speed of the complete pattern, -20Hz to +20Hz, positive values for
CCW rotation
Phase
–
Relative phase rotation of the complete pattern, -359 degrees to 359 degrees