5.8.4 Line
Figure 5-18, Setup Pattern, Line
Freq
–
Frequency, 0.1Hz to 80Hz
Rotation
–
Rotation speed of the complete pattern, -20Hz to +20Hz, positive values for
CCW rotation
Phase
–
Controls the angle of the line (only visible when the rotation is 0), -359 degrees
to 359 degrees
Amp
–
Amplitude, 20-100% of configured maximum pocket
LDC Tail
–
Display of the history of the pattern, 10 to 1000
Profile
- -10.0 to 10.0
5.8.5 Circle
Figure 5-19, Setup Pattern, Circle
Freq
–
Frequency, 0.1Hz to 80Hz
Collapse
- Collapse, 0 to 5Hz. (if collapse is 0 then the Amp In is not visible)
Amp In
–
Amplitude In, 5-100% of configured maxim pocket (only when the collapse
greater than 0)
Amp Out
–
Amplitude Out, 10-100% of configured maximum pocket
LDC Tail
–
Display of the history of the pattern, 10 to 1000