Programmable Sweep Instruction Manual
CONFIGURATION
telemark.com
43 of 58
Rev 1.0.0
5.8.6 Spiral
Figure 5-20, Setup Pattern, Spiral
Freq
–
Frequency, 0.1Hz to 80Hz
Rotation
–
Rotation speed of the complete pattern, -20Hz to +20Hz, positive values for
CCW rotation
Phase
–
Controls the angle of the line (only visible when the rotation is 0), -359 degrees
to 359 degrees
Amp
–
Amplitude, 20-100% of configured maximum pocket
LDC Tail
–
Display of the history of the pattern, 10 to 1000
Profile
- -10.0 to 10.0
5.8.7 Point
Figure 5-21, Setup Pattern, Point
The point pattern is a fixed point and location is a special case. The lat and long
numbers displayed are the absolute location numbers. A maximum of 97% of
configured pocket maximum in any direction is designed to prevent users from
damaging the ebeam source pocket.
Lat
–
Latitudinal position, -511 to +511 (-97% to +97% of configured pocket maximum)
Long
–
Longitudinal position, -511 to +511 (-97% to +97% of configured pocket
maximum)