9.11  Adjusting backlight 

Navigate to the tab sheet 

[General]

 in the application 

 Settings. 

9.11.1 

Automatic adjustment 

If you want the brightness of the display to adjust automatically, tap on the gray 

[OFF]

 switch 

under <Auto Brightness>. 

  Brightness is automatically adjusted. 

  The blue 

[ON]

 switch is active. 

  Brightness scale with brightness slider is inactive. 

 
 

9.11.2 

Manual adjustment 

If you want to adjust the brightness of the display manually, tap on the blue 

[ON]

 switch under 

<Auto Brightness>. 

  The gray 

[OFF]

 switch is active. 

  Brightness scale with brightness slider is active. 

 
Swipe the brightness slider to the desired position or 
tap on the desired position on the brightness scale. 

  Brightness is set according to adjustment. 

  A brief fade-in indicates the new brightness value set in percent. 

 

 

Figure 9.1: Fade-in after adjusting the brightness 

 

 

9.12  Adjusting volume 

Note: 
A tone is produced to simulate the newly set volume. If you set the volume to “Volume: 
0%”, the RCTouch is mute. Its acoustic signals are inaudible. 

Navigate to the tab sheet 

[General]

 in the application 

 Settings. 

Swipe the volume slider to the desired position or 
tap on the desired position on the volume scale. 

  A change in volume is indicated by a tone and at the same time it simulates the new-

ly set volume. 

  A brief fade-in indicates the new volume value set in percent. 

 

Summary of Contents for blue PiraT Mini

Page 1: ...Remote Control Touch User Guide Version 2 1 1 08 12 2015...

Page 2: ...1 Top view 12 7 1 2 Side view from the right 13 7 1 3 Rear side 13 7 2 Functionality of components 14 7 2 1 Ports 14 7 2 2 Brightness sensor 14 7 2 3 Home button 14 7 2 4 Speaker 14 7 2 5 LEDs 15 7 2...

Page 3: ...finiert 9 8 Setting and deleting complex triggers Fehler Textmarke nicht definiert 9 9 Setting triggers Fehler Textmarke nicht definiert 9 9 1 Trigger with voice note Fehler Textmarke nicht definiert...

Page 4: ...t entitled to transmit or to transfer the software or its rights from this license agreement 6 Licensor is not liable to licensee for any damages including compensatory special incidental exemplary pu...

Page 5: ...negligence or other legal or equitable theory 5 The burden of proof is with the customer 6 The Telemotive AG does ensure the legal warranty according to German law Except for warran ties expressly set...

Page 6: ...rosoft Windows 7 This document refers to blue PiraT Mini firmware version 02 02 01 and the Telemotive Sys tem Client version 2 2 1 Some features depend on model and feature license or may not be avail...

Page 7: ...software client for the blue PiraT2 blue PiraT2 5E and blue PiraT Mini the TSL client Telemotive System Link is needed to configure the data logger and later to download or con vert the recorded data...

Page 8: ...ced with a fuse of the same type and nominal current rating Storage The device may only be stored within a temperature range of 40 F to 185 F Disposal Disposal of the device must be in accordance with...

Page 9: ...operating instructions always providing for a spare fuse in the cable set Clamp 15 KL 15 serves as an external wake up input It can be used to wake up the device in case of edge change KL 15 requires...

Page 10: ...d party devices is at your own risk Its use while driving is at your own risk If you are using the device while driving we strongly recommend to focus your attention on the road traffic and the safety...

Page 11: ...act discharge 8 kV air discharge CE label TBD Operating temperature 4 F to 158 F Storage temperature 40 F to 185 F Weight approx 410 g Power management Startup time from standby to full operation 35 s...

Page 12: ...e PiraT Mini and blue PiraT2 data loggers or a TSL network The RCTouch allows you to display bus load status and memory of available interfaces display date and time trigger function keys display set...

Page 13: ...1 doc 7 1 2 Side view from the right 1 8 pol LEMO socket 2 Gbit Ethernet RJ45 3 Gbit Ethernet RJ45 Figure 7 2 Side view from the right with components 7 1 3 Rear side 4 Mini USB 2 0 5 4 pol audio jack...

Page 14: ...ana plug or Power cable with Lemosa connector to DIN plug Power source 2 Gbit Ethernet RJ45 Gbit Ethernet cable Client computer or data logger 3 4 Mini USB 2 0 Micro USB connecting cable USB devices 5...

Page 15: ...s are compatible with the RCTouch mounting bracket various adapter cables including power cables Please contact our sales department for more information about the accessories The relevant manuals for...

Page 16: ...e RCTouch only with devices of Telemotive AG blue PiraT Remote Control 7 4 1 1 With power supply Note Make sure that the RCTouch is switched off before connecting it with a power supply or disconnecti...

Page 17: ...t of the blue PiraT 7 4 1 2 In the network The RCTouch has two Ethernet ports The loggers to be controlled are connected directly via Ethernet to the RCTouch These loggers must establish a TSL network...

Page 18: ...locally save the file on your system Click Accomplish Mozilla Firefox Click Save file to locally save the file on your system Click the arrow on the right top of the browser menu and select the down...

Page 19: ...or the applications Driver View and Settings the num ber and naming of the tabs is set Figure 8 1 Application sitemap Note n stands for any number of devices When an application is launched for the fi...

Page 20: ...ication views 8 1 1 Header bar In each view the header bar contains the designation of the current view and date and time of the device or the TSL network Depending on the operating mode two represent...

Page 21: ...active tab is further characterized by a narrow bright yellow margin above 8 2 Applications An icon has been set for each of the four applications to find them more easily In the Home view and the sid...

Page 22: ...ach GPS resp MOST inter face is assigned a tab sheet The application Status contains minimum two tab sheets the tab sheet Overview and the tab sheet of the RCTouch with the name assigned in the client...

Page 23: ...t shown on its tab sheet 8 3 3 Functionkeys The window of the tab sheet Functionkeys contains two buttons on the left and ten function keys on the right The function keys can be assigned complex trigg...

Page 24: ...note This is indicated by the button in the marker entry Figure 8 7 Tab sheet Markerlist 8 3 5 CAN Serial LIN Ethernet Camera CCP_XCP Each of these tab sheets contains a tabular overview of all channe...

Page 25: ...e window contains only the display of Light off the cable is incorrectly connected or no MOST data is sent and the bus is inactive Figure 8 10 Tab sheet MOST150 Light off 8 3 7 GPS Each connected logg...

Page 26: ...or too few satellites were found minimum 3 Figure 8 13 Tab sheet GPS No GPS signal 8 3 8 General The window of the tab sheet General contains a total of five control elements 1 Brightness scale with...

Page 27: ...ghtness slider is inactive OFF switch Brightness is adjusted according to the position of the brightness slider on the brightness scale Brightness scale with brightness slider is active Volume scale w...

Page 28: ...tected can be configured under General Buffer indicates the percentage of the memory capacity that is protec ted 8 3 2 IP address indicates the IP address of the device 8 3 1 8 3 2 Channel name can be...

Page 29: ...section 10 5 Memory space and level The following types of devices exist Message Type RCTouch Remote Control Touch BP Mini blue PiraT Mini BP2 MB1 x blue PiraT2 BP2 MB2 x blue PiraT2 5E Table 8 5 Devi...

Page 30: ...RCTouch and or views that appear outside the application 8 5 1 AlertDialog Precondition none Timing Internal communication has failed Options close popup To close the popup tap on OK Then repeat the l...

Page 31: ...in Launcher view Index 8 5 4 RC Monitor Precondition Optional Remote Control Monitor license is installed An application is open Timing Complex trigger configured to the Action Display Remote Control...

Page 32: ...condition An application is open Timing Complex trigger configured to the Action Display notification on Re mote Control is actuated see section 9 20 Options set trigger close view The view is not upd...

Page 33: ...me button or tap on the display 8 6 Restrictions in standalone mode 8 6 1 RCTouch applications In standalone mode the RCTouch is not connected to any data logger Some functions are therefore not avail...

Page 34: ...ata 4 Open configuration 5 Update firmware 6 Open bug report Figure 8 20 Tab Network Logger in the TSL network Find more information about the client applications in a TSL network in the Telemotive Sy...

Page 35: ...in the Telemotive System Client user guide chapters 15 and 16 The application Open configuration 4 provides less categories in the configuration tree e g General and less sub items e g Name than for a...

Page 36: ...the configuration for the Event Key Stroke using a function key as Key Index 9 1 Adjusting backlight Navigate to the tab sheet General in the application Settings 9 1 1 Automatic adjustment If you wa...

Page 37: ...and at the same time it simulates the new ly set volume A brief fade in indicates the new volume value set in percent Figure 9 2 Fade in after adjusting the volume Index 9 3 Changing application To r...

Page 38: ...The quality of the recording and playback is dependent on the Speaker and Micro phone settings on the tab sheet General see section 8 3 8 Navigate to the tab sheet Markerlist in the application Drive...

Page 39: ...eet you have the option to scroll Swipe the tab sheet vertically upwards Window is scrolled down downwards Window is scrolled up If the window reached the very top or bottom this is indicated by a gra...

Page 40: ...the source device TSL wide events are not supported Double click on Add Trigger New trigger is generated and displayed in the configuration tree e g Trigger 1 The window Trigger opens Note If the trig...

Page 41: ...popup with an error message would appear Figure 9 7 Error message due to unauthorized configuration Edit the action specific settings Click on Write to logger Configuration is transferred to the logge...

Page 42: ...sheet Functionkeys Index 9 9 Setting triggers Navigate to a tab sheet in the application Driver View 9 9 1 Trigger with voice note Note The quality of the recording and playback is dependent on the se...

Page 43: ...Uploaded record Sound recording is uploaded button appears in the Marker entry Figure 9 11 Voice note recording stops Index 9 9 2 Trigger without voice note Note Setting a trigger without voice note...

Page 44: ...ion Changing tab sheet 9 18 Scrolling through tab bar 9 15 Opening and closing side menu 9 21 Setting triggers 9 16 Playing voice note Functionality of the components is impaired by certain conditions...

Page 45: ...Brightness scale with brightness slider is active Swipe the brightness slider to the desired position or tap on the desired position on the brightness scale Brightness is set according to adjustment...

Page 46: ...tab sheets within an application tap in the tab bar on the tab of the desired tab sheet Selected tab sheet appears To reach tab sheets in other applications switch to the application of the desired t...

Page 47: ...on display If you tap on a second button while the voice note is played the playback is stopped and the second voice note is played If you want to stop playing the voice note prematurely tap on the bu...

Page 48: ...wards Window is scrolled down downwards Window is scrolled up If the window reached the very top or bottom this is indicated by a gray margin on the top re spectively bottom of the display 9 20 Settin...

Page 49: ...rigger New trigger is generated and displayed in the configuration tree e g Trigger 1 The window Trigger opens Note If the trigger configuration is not complete this is indicated by a red symbol with...

Page 50: ...thorized configuration Edit the action specific settings Click on Write to logger Configuration is transferred to the logger Note If you select Key Stroke as the Event using a function key as Key the...

Page 51: ...s dependent on the settings of Speaker and Microphone on the tab sheet General see section 8 3 8 Tap on Record to set a trigger with voice note on the connected devices Sound recording starts Recordin...

Page 52: ...u do not hear an acoustic signal increase the volume see section 9 12 Tap on Trigger to set a trigger on the connected devices A tone sequence indicates that a marker was set A brief fade in tells you...

Page 53: ...ith warning disappears The RCTouch is switched on when the tab sheet Overview appears and the Active LED flashes green 9 24 Updating firmware Find more information on firmware update in the Telemotive...

Page 54: ...m bers Under New firmware click on Open Dialog opens Index Select the desired firmware Click on Open Note For the RCTouch you need the same firmware as for the blue PiraT Mini Figure 9 14 Opening firm...

Page 55: ...igure 9 16 Notice message for invalid firmware packet Click on Update firmware Firmware file is verified Dialog opens Index Figure 9 17 Notice message before firmware update Follow the dialog instruct...

Page 56: ...Guide Datum 08 12 2015 Seite 56 von 61 RCTouch_UserGuide_V2 1 1 doc Figure 9 18 Advancing firmware update The firmware is updated when the view FW Update disappears the State LED goes out and the Clo...

Page 57: ...ive System Client CAN Controller Area Network LIN Local Interconnect Network MOST Media Oriented Systems Transport www mostnet de ECL Electrical Control Line MEP MOST Ethernet Packet USB Universal Ser...

Page 58: ...gnal 26 Figure 8 14 FW Update view 30 Figure 8 15 Launcher view 31 Figure 8 16 Popup in Launcher view 31 Figure 8 17 Window RC Monitor 32 Figure 8 18 Window RC Text 32 Figure 8 19 Standby view 33 Figu...

Page 59: ...ble 7 1 Available connections 14 Table 7 2 LED behavior 15 Table 8 1 Application overview 21 Table 8 2 Operating elements of the tab sheet General 27 Table 8 3 Displays overview 28 Table 8 4 Device st...

Page 60: ...Remote Control Touch User Guide Datum 08 12 2015 Seite 60 von 61 RCTouch_UserGuide_V2 1 1 doc 13 Version history Version nderung Abteilung Name Datum Table 13 1 Version history Index...

Page 61: ...nkfurter Ring 115a 80807 M nchen Tel 49 89 357186 0 Fax 49 89 357186 520 E Mail info telemotive de Web www telemotive de Sales Tel 49 89 357186 550 Fax 49 89 357186 520 E Mail sales telemotive de Supp...

Reviews: