Status Registers
V.3600
10-15
Remote Configuration Guard Time — S42
Select the remote configuration guard time (0-255) in 20 ms intervals.
The default is 50 (1 sec).
S43
Reserved
XON Character from DTE — S44
Select the XON character (0-127) to be sent from the DTE. The default
value is ASCII 17.
XOFF Character from DTE — S45
Select the XOFF character (0-127) to be sent from the DTE. The default
value is ASCII 19.
S46-48
Reserved
XON Character to DTE — S49
Select the XON character (0-127) to be sent to the DTE. The default
value is ASCII 17.
XOFF Character to DTE — S50
Select the XOFF character (0-127) to be sent to the DTE. The default
value is ASCII 19.
Dial Line Transmit Level — S51
The
S51
register selects dial line transmit level from -9 to -30 dBm in 1
dBm increments. The default value is 10.
Bit
Value
Command
Description
4-0
0 to
30
*TDn (n=9
to 30)
Transmit level in dBm (-9 through -30 dBm)
7-5
--
--
Reserved