Installation
Housing
The amplifier can be installed either into a street cabinet or to outdoor
environment. The amplifier should be installed in a vertical position so that the
external cable connectors are underneath. At least 100 mm of free space
should be left above the amplifier to ensure sufficient cooling air circulation. The
class of enclosure is IP54. Note, used connector type might have lower IP-
classification than the amplifier housing.
The cover of the housing is closed by a single bolt. There are no hinges. Open
cover is to be removed completely. When closing the cover use a PZD 2
screwdriver to tighten the bolt to a torque of 2.5...3.5 Nm. To ground the
amplifier housing connect at least 4 mm
2
grounding wire (Cu) from a proper
earth to the grounding point.
NOTE! Make sure the input attenuator adjustment (Figure 4 pos. 5) is at its
minimum level before connecting power to the amplifier.
8910044
Figure 1. CXE180 amplifier
1) Input, 2) Ground, 3) Output port 2, 4) Output port 1
Interfaces
Underneath the CXE180 amplifier there are three cable connection points: input
and two outputs. The amount and function of actual connectors varies with the
chosen configuration.
All coaxial connection points have a standard PG11 thread and they accept a
KDC type adapter or connector. Available connector types are F, IEC, PG11,
5/8” and 3.5/12.
8905010
Figure 2. Centre conductor length