background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Remote Digital Display Unit 

DS-10 

2-7900-098 

Instruction Manual

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

TELEVAC 

A DIVISION OF  

THE FREDERICKS COMPANY

 

2400 PHILMONT AVE. 
HUNTINGDONVALLEY, PA  19006

 

 
 
 

SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:szss20@163.com

SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:szss20@163.com

Summary of Contents for DS-10

Page 1: ...AC A DIVISION OF THE FREDERICKS COMPANY 2400 PHILMONT AVE HUNTINGDONVALLEY PA 19006 SUNSTAR传感与控制 http www sensor ic com TEL 0755 83376549 FAX 0755 83376182 E MAIL szss20 163 com SUNSTAR传感与控制 http www sensor ic com TEL 0755 83376549 FAX 0755 83376182 E MAIL szss20 163 com ...

Page 2: ...S 10 25 25 25 45 0 6 0 6 0 0 L1 n number of unit 2 n 6 45 L1 48 n 3 44 8 25 0 6 0 45 0 6 0 SUNSTAR传感与控制 http www sensor ic com TEL 0755 83376549 FAX 0755 83376182 E MAIL szss20 163 com SUNSTAR传感与控制 http www sensor ic com TEL 0755 83376549 FAX 0755 83376182 E MAIL szss20 163 com ...

Page 3: ...t 2 NO 8 SP3 Setpoint 3 NO 9 SP2 SP3 COM Setpoint 2 3 Common 11 ANALOG IN INPUT Analog Input 12 ANALOG IN Analog input 24V NO 10 NO 0 10V SP1 NO NC DC 13 14 15 18 16 17 3 6 5 4 2 1 12 11 9 7 8 SP3 SP2 SUNSTAR传感与控制 http www sensor ic com TEL 0755 83376549 FAX 0755 83376182 E MAIL szss20 163 com SUNSTAR传感与控制 http www sensor ic com TEL 0755 83376549 FAX 0755 83376182 E MAIL szss20 163 com ...

Page 4: ...reen Input signal Input voltage DC 0 10V Sampling interval 0 5sec Input impedance 5 1kohm Setpoint Setpoint 1 AC250V 3A 1c contact Setpoint 2 3 AC250V 1A 1a contact Ambient Temperature 0 50 Humidity 45 85 RH Power Input voltage DC21 6 26 4V nominal 24V power consumption max 160mA physical property weight 150g size 48 48 100mm SUNSTAR传感与控制 http www sensor ic com TEL 0755 83376549 FAX 0755 83376182 ...

Page 5: ...played values 7 Up key increase displayed values 5 Operation When power is turned on model number and software version number are displayed for 4 seconds then go to measure mode 4 seconds DS 10 SET SP2 SP1 SP3 10 SET SP1 SP2 SP3 DS 10 10 SP1 SET DS 10 10 SP3 SP2 model number soft version measure mode SP3 10 SP1 SP2 SET DS 10 SUNSTAR传感与控制 http www sensor ic com TEL 0755 83376549 FAX 0755 83376182 E...

Page 6: ...Push shift key to move changing digit 2 Push down key to change the value from 2 to 1 3 Push set key to register the value The unit automatically move to the next parameter 10 DS 10 SP1 SP2 SP3 SET SET SP1 SP2 SP3 DS 10 10 10 DS 10 SP1 SP2 SP3 SET DS 10 SP3 SP2 SP1 SET 10 SET SP3 SP2 SP1 DS 10 SP1 SET DS 10 SP3 SP2 10 10 SP3 10 SP1 SP2 SET DS 10 SP3 SP1 10 SP2 DS 10 SET SUNSTAR传感与控制 http www senso...

Page 7: ... SP1L SP2 upper threshold SP2H SP2 lower threshold SP2L SP3 upper threshold SP3H SP3 lower threshold SP3L digital filter dF SET SP1 SP2 SP3 DS 10 10 10 SET SP3 SP2 SP1 DS 10 SUNSTAR传感与控制 http www sensor ic com TEL 0755 83376549 FAX 0755 83376182 E MAIL szss20 163 com SUNSTAR传感与控制 http www sensor ic com TEL 0755 83376549 FAX 0755 83376182 E MAIL szss20 163 com ...

Page 8: ...t data range 0000 Blinking Over scale uuuu Blinking Under scale SUNSTAR传感与控制 http www sensor ic com TEL 0755 83376549 FAX 0755 83376182 E MAIL szss20 163 com SUNSTAR传感与控制 http www sensor ic com TEL 0755 83376549 FAX 0755 83376182 E MAIL szss20 163 com ...

Reviews: