EN
5
COFDM input
Input frequency (selec.)
MHz
177,5 - 226,5 / 474 - 858
Input return losses (typ.)
dB
>10
Frequency steps (selec.)
KHz
125, 166
Bandwidth
MHz
7; 8
Input level
dBm
-60 to -20
Input through losses (typ.)
dB
< 1.5
Input connectors
type
“F” - female
Powering for preamps (selec.)
Vdc
0, 12, 24
Impedance
ohm
75
QAM
Modulator
Modulation format
QAM
16, 32, 64, 128, 256
Scrambling
DVB ET300429
Symbol rate (max.)
Mbaud
6.9
Interleaving
DVB ET300429
Roll-off fator
%
15
Bandwidth (max.)
MHz
8.3
Block code
Reed Solomon (188, 204)
Spectral inversion (selec.)
Normal / Inverted
QAM output
Output frequency (selec.)
MHz
46 - 862
Output through losses (typ.)
dB
< 1.5
Frequency steps
KHz
250
Output through losses (typ.)
dB
> 12
Output level (max.)
dBμV
80 ±5
Input/Output connectors
type
“F” female
Attenuation (progr.)
dB
>15
Impedance
ohm
75
General
Consumption 24Vdc
(with signal)*
Vdc
270 (no CAM inserted; preamplifi ers powering OFF)
370 (CAM inserted; preamplifi ers powering OFF)
320 (no CAM inserted; preamplifi ers powering ON)
420 (CAM inserted; preamplifi ers powering ON)
Protection index
IP20
1. Technical specifi cations
1.1. COFDM-QAM CI ref. 563601
* The unit’s consumption with CAM will depend on the type of CAM being used. For preamplifi ers it is considered a standard consumption of 50mA.
The Power Supply Unit is able to powering up to seven COFDM-QAM CI modules maximum.
Is necessary to use both PSU outputs when consumption of one of them exceeds 4A (maximum current in each output).
The technical characteristics described are defi ned for a maximum ambient temperature of 45°C (113ºF). Forced ventilation must be used for higher temperatures.