background image

Installation

Unpacking

The package contains the following items. Contact the shipper or your Audiocom

dealer immediately if anything is damaged or missing. Detach and fill out the regis-

tration card and return it to Telex to properly register your SPS2000A.

Quantity

Description

1

SPS2000A Power Supply

1

Warranty and registration card

1

User Manual

4

Rubber feet (install for desktop use of the SPS2000A)

1

Power cord

Configuration Switches

WARNING

The following instructions are for use by qualified personnel only.
To avoid electric shock, do not remove the cover unless you are
qualified to do so.

AVERTISSEMENT

Les instructions qui suivent s'adressent uniquement a un techni-
cien qualifie. Pour evite des chocs electriques, ne pas ouvrir le
boitier, a moins d'y entre habilite.

The Audiocom / Clear-Com switch (S200) is factory set for use with Audiocom in-

tercom stations. Before using the SPS2000A with Clear-Com, remove the top cover

and change the setting as shown in Figure

2

The top cover is secured by five screws

on the top and three screws on each side.

The Combine / Isolate switch position may be changed at any time by inserting a pen

point or other small object through the front panel. When the switch is in the Com-

bine position, all users on both channels may intercommunicate. When the switch is

set to the Isolate position, channels 1 and 2 cannot intercommunicate.

Intercom Channel and Program Connections

Channel Capacity: When connecting intercom stations to the SPS2000A, determine

the total current for all stations on each channel. The total per channel should not ex-

ceed 2A. If you exceed this limit, the SPS2000A will provide an overload indication.

6

Au d i o c o m ®

Summary of Contents for Audiocom SPS2000A

Page 1: ...T elex User Instructions Model SPS2000A Power Supply Audiocom Intercom Systems SPS2000A RESET 1 R 2 Volum e ...

Page 2: ...ed in a commercial environment Operation of this equipment in a residential area may cause interference which the user at his own expense will be required to correct This product meets Electromagnetic Compatibility Directive 89 336 EEC Introduction Thank you for purchasing the Audiocom SPS2000A Power Supply We hope that this power supply used together with your Audiocom User Stations will satisfy ...

Page 3: ...ble of Contents Description 4 Installation 6 Unpacking 6 Configuration Switches 6 Intercom Channel and Program Connections 6 Power Up Check 11 Specifications 13 Factory Service and Parts Information 14 3 ...

Page 4: ...k mounting optional hardware is required For desktop use four non marring rubber feet are supplied 1 Speaker Inputs and Volume Control Two audio inputs are provided The inputs are combined internally and sent as a monaural signal to the internal speaker amplifier The Volume control adjusts the level to the front panel speaker Typi cally these inputs are used with the speaker outputs of a master st...

Page 5: ...cepts any input power in the range of 100 240 VAC 50 60 Hz 5 Intercom Channel Connectors When the Combine Isolate switch is set to the Isolate position each channel connector is powered separately and has com pletely separate intercom audio When the Combine Isolate switch is set to the Combine position each channel is still powered separately but the audio signals are combined so that all users on...

Page 6: ...rir le boitier a moins d y entre habilite The Audiocom Clear Com switch S200 is factory set for use with Audiocom in tercom stations Before using the SPS2000A with Clear Com remove the top cover and change the setting as shown in Figure 2 The top cover is secured by five screws on the top and three screws on each side The Combine Isolate switch position may be changed at any time by inserting a pe...

Page 7: ...hown in Figure 3 Speaker interconnect cables are standard RCA phono types For program input cable wiring refer to your master intercom station user manual Some typical intercom system applications are shown in Figures 4 through 6 Clear Com Applications Refer to your Clear Com system documentation for inter com cable wiring and connection details 7 Figure 2 Audiocom Clear Com Selector Switch Top Co...

Page 8: ...enerally constructed using a male connector at one end and a female connector at the other end This allows several cables to be interconnected to create longer cable runs Audiocom power supplies use a 3 pin male Neutrik connector for each channel Audiocom wallplates use male Neutrik connectors Audiocom master stations speaker stations and belt packs also typically provide both a male and female Ne...

Page 9: ...NES HEADSET LINES BP 1000 BP 1000 BP 1000 BP 1000 BP 1000 BP 1000 BP 2000 BP 2000 Note A JB 2 Junction Box may be used instead of the Y cables The JB 2 provides a means of combining two channels while also allowing the single channels to be continued directly from the junction box CHN 1 CHN 2 CLASS 2 WIRING 1 5A 24VDC 100 240 VAC 60 50 HZ MADE IN USA INPUT 1 SPEAKER INPUT 2 LINE LEVEL 1 VRMS Figur...

Page 10: ...DSET LINES HEADSET LINES HEADSET LINES HEADSET LINES HEADSET LINES BP 1000 BP 1000 BP 1000 BP 1000 BP 1000 BP 1000 BP 2000 BP 2000 Note A JB 2 Junction Box may be used instead of the Y cables The JB 2 provides a means of combining two channels while also allowing the single channels to be continued directly from the junction box CHN 1 CHN 2 CLASS 2 WIRING 1 5A 24VDC 100 240 VAC 60 50 HZ MADE IN US...

Page 11: ... A EXP OUT CHN 2 VOL PGM 2 VOL PGM 1 BAL OUT UNBAL IN PUSH PUSH CHN 1 To of stations on channel 2 To of stations on channel 1 To of stations on channel 2 To of stations on channel 1 SPS2000A Channel 1 Power Combine Isolate Switch set to Combine US2000A Internal DIP switches set for binaural operation SPS2000A Channel 2 Power Combine Isolate Switch set to Combine 1 1 1 1 1 1 1 Denotes 1 channel cab...

Page 12: ...s indicators should be green 3 If a channel status indicator turns red during operation try correcting the prob lem by pressing the reset button on the front of the SPS2000A If the problem persists unplug the SPS2000A and locate the short or overload that is causing the problem 12 Audiocom ...

Page 13: ...t depends on setting of internal switch S200 for balanced or unbalanced operation as defined below Balanced Mode S200 set to BAL position Line Terminating Impedance 300 ohms 10 Connector Pin out Pin 1 Common audio and DC return Pin 2 Full duplex balanced intercom audio and 24 VDC output Pin 3 Full duplex balanced intercom audio and 24 VDC output Unbalanced Mode S200 set to UNBAL position Line Term...

Page 14: ...r must be sent prepaid and will be returned prepaid Non Warranty Repairs Equipment that is not under warranty must be sent prepaid to Telex If requested an estimate of repair costs will be issued prior to service After your approval and completion of the repairs the equipment will be returned on a col lect basis Collect charges may be avoided by sending a signed check for payment in full along wit...

Page 15: ...Notes 15 ...

Page 16: ...TELEX COMMUNICATIONS INC 9600 Aldrich Ave So Minneapolis MN 55420 U S A 9350 7333 010 Rev A2 8 97 ...

Reviews: