Quick set-up:
Handheld Transmitter.
1. Insure that the Power switch in Transmitter is in the OFF position.
2. Install a fresh Alkaline Battery into the transmitter.
3. Insure that the Microphone Gain Control is set at about 50 % of
rotation.
4. Check the position of the Transmit Power Switch. If this is a single
microphone System, place the switch in the High Power position. If
this is a multiple microphone system, particularly when used with
other non-coordinated units and intermod is experienced, placing the
Transmit Power Switch to “Norm” will frequently eliminate
intermod.
5. Place the transmitter Power Switch to the ON position.
6. The Red Low Battery Light near the display should come on for a
few seconds. The display will also come on briefly, displaying two
screens of software versions.
7. The screen will stop at the GP (Group) and CH (Channel) screen. If
the Group and Channel agree with the receiver Group and Channel,
proceed to step 8. If the Group and Channel do
not
agree with the
receiver, go to step 10.
8. Monitor the SAFE-1000 Receiver 1
st
operating screen. Note that the
RF (1-100) Bar graph should indicate near the 100 mark. The AF Bar
should show very little If any indication until you talk or sing into
the microphone. Adjust the microphone gain control
if necessary
to
cause the AF Bar Graph to peak near –6 to –3 but not over +3 for
best performance.
9. If you are satisfied with the Group/Channel and audio screen
displays, the mixer or sound system gain/volume can be increased to
monitor the sound.