S1 - Ring Counter
ATS1
S1
is incremented each time the device detects the ring signal of an incoming call.
S1
is cleared as soon as no ring occur.
Note: the form
ATS1
has no effect.
ATS1?
Read command returns the value of this parameter.
S3 - Command Line Termination Character
ATS3=<char>
Set command sets the value of the character either recognized by the device as
command line terminator or generated by the device as part of the header, trailer,
and terminator for result codes and information text, along with
S4
parameter
.
Parameter:
<char>
- command line termination character (decimal ASCII)
0..127 - factory default value is 13 (ASCII
<CR>
)
Note: the “previous” value of
S3
is used to determine the command line termination
character for entering the command line containing the
S3
setting command.
However the result code issued shall use the “new” value of
S3
(as set during the
processing of the command line)
ATS3?
Read command returns the current value of
S3 parameter
.
Note: the format of the numbers in output is always 3 digits, left-filled with 0s
Reference
V25ter
S4 - Response Formatting Character
ATS4=<char>
Set command sets the value of the character generated by the device as part of the
header, trailer, and terminator for result codes and information text, along with the
S3 parameter
.
Parameter:
<char>
- response formatting character (decimal ASCII)
0..127 - factory default value is 10 (ASCII
LF
)
Note: if the value of
S4
is changed in a command line the result code issued in
response of that command line will use the new value of
S4
.
ATS4?
Read command returns the current value of S4 parameter.
Note: the format of the numbers in output is always 3 digits, left-filled with 0s
Reference
V25ter
S5 - Command Line Editing Character
Summary of Contents for LE910-SKG